Comparison of rebound tonometry with applanation tonometry for intraocular pressure measurement
Journal Title: Indian Journal of Clinical and Experimental Ophthalmology - Year 2017, Vol 3, Issue 3
Abstract
Purpose: To compare the readings of the Goldmann’s applanation tonometry with that of the iCare Ta01i in Indian patients. Materials and Methods: Intraocular pressure measurements were obtained in 440 eyes of 220 subjects in which 320 were normal eyes and 120 eyes had a high IOP. A thorough examination was done and IOP was measured in all subjects using iCare Ta01 tonometer and the Goldmann’s applanation tonometer 3 times each and the average was taken. All examinations and measurements were done by the same 2 personnel. Results: Intraocular pressure measurements with ICare Ta01 tonometer compared with the Goldmann’s applanation tonometer were not found to have a significant difference (mean ±2.34mmHg). The 95% confidence interval between readings with the 2 methods was within acceptable limits. Conclusion: The ICare Ta01 tonometer measurement of intraocular pressure showed excellent correlation with those from the Goldmann applanation tonometer, which is the gold standard for IOP measurement. The iCare, with all its advantages over the GAT, can be used as a routine instrument for measurement of IOP in ophthalmology practice.
Authors and Affiliations
CN Madhusudhana, S Shyam
A four year retrospective & prospective study of ophthalmia neonatorum
Introduction: Ophthalmia neonatorum is one of the most common infections occurring in the first month of life. 1 Neonatal ocular infections have been largely associated with various poor perinatal outcomes. The purpose o...
A study of etiological causes of severe visual impairment and blindness in children of Western Rajasthan
Childhood blindness are group of conditions that occurs in childhood or early adolescence (<16 years of age), and if left untreated, results in severe visual impairment or blindness that is likely to be not treatable lat...
A study on refractive errors in school children with complaints of headache in a rural tertiary care hospital
Purpose: To evaluate refractive errors among school children with complaints of headache and to compare it with children without headache. Methods: This is a prospective cross-sectional study of 414 school children with...
Strabismus surgery complications
Serious complications during or after strabismus surgery are infrequent This article gives a brief idea of the complications either local or systemic that can occur during or after squint surgery Meticulous hemostasis is...
Phaco chop versus stop and chop nucleotomy techniques: A comparative evaluation
To perform a comparative evaluation of phaco chop versus stop and chop nucleotomy techniques in phacoemulsificationMaterials and Methods 60 patients with uncomplicated senile cataract were included in this study which we...