Comparison of the effects of two different dose algorithms in cardiac dose parameters for hodgkin lymphoma patients receiving mediastinal radiotheraphy

Journal Title: Medical Science and Discovery - Year 2016, Vol 3, Issue 8

Abstract

Objective:  This study aimed to compare pencil beam (PB) and convolution superposition (CS) dose calculation algorithms with respect to cardiac dose-volume parameters V5, V25, V30 and MHD (median heart dose) in Hodgkin lymphoma (HL) patients who received mediastinal radiotherapy (RT).Material and Methods:  Ten eligible cases with the diagnosis of HL who completed mediastinal RT at Dokuz Eylül University Department of Radiation Oncology before 01.01.2011 formed the study population.  Related 3D conformal RT treatment plans were obtained from the Treatment Planning System (TPS) (Nucletron Oncentra Master Plan Version 3.3 SP3 program). Calculations were done for 6 and 18 MV-X beam energy, respectively by using PB and CS algorithms in the TPS. Two algorithms were compared in terms of cardiac dose-volume parameters (V5, V25, V30 and MHD).Results: Mean relative difference for both V25 and V30 was found to be significantly higher in favor of PB algorithm in both 6 MV-X and 18 MV-X photon energy.  Mean relative differences were 1.75% (p=0.012) and 6.76% (p=0.028) for the V25 and V30 parameters, respectively in 6 MV-X and 3.25% (p=0.021) and 13.95% (p=0.007) for the V25 and V30 parameters, respectively in 18 MV-X energy.Conclusion:  When PB algorithm is used in RT treatment planning of HL patients for the mediastinal region where tissue inhomogeneity is relatively high, heart V25 and V30 parameters were shown to result in higher values compared to CS algorithm in our study.  It is more appropriate to prefer CS algorithm instead of  PB algorithm since it increases accuracy of calculations in the treatment planning of mediastinal RT.

Authors and Affiliations

Emre Tahberer, Ahmet Cinkaya, Yasin Coban, Serdar Surenkok, Mehmet Adigul, Ahmet Ergin Capar

Keywords

Related Articles

Aldehyde dehydrogenase-1 expression and prognosis in triple-negative breast cancer

Objective: Understanding of other biological characteristics of Triple-negative breast cancer, the development of new therapeutical approaches and identification of new markers is necessary due to the lack of biological...

Tumor Mimicking Bladder Endometriosis

Endometriosis is described as the presence of endometrial tissue outside the uterine corpus. Though urinary tract endometriosis is uncommon, the bladder is the most common localization amongst them. Here we present three...

The analysis of adult intoxication cases seen in Adıyaman Region and treated in intensive care unit

Objective: We determined the patient profile and aim to look into the distribution of age and sex, intoxication route, the duration of the stay in ICU and prognosis of the cases we accepted to our ICU presenting with int...

Recurrent ovary cancer presenting with scleroderma - A rare case report

Scleroderma is a chronic autoimmune multisystem disorder which is characterized by progressive fibrosis of the skin and internal organs. Ovary cancers with scleroderma have been reported in the literature. But recurrent...

Extreme pulmonary artery aneurysm with thrombosis

A 52-year-old male patient had a right humorous fracture 6 weeks before seeking surgical treatment. On transthoracic echocardiography, the pulmonary artery aneurysm was measured, at its widest point, to be approximately...

Download PDF file
  • EP ID EP520527
  • DOI 10.17546/msd.57676
  • Views 45
  • Downloads 0

How To Cite

Emre Tahberer, Ahmet Cinkaya, Yasin Coban, Serdar Surenkok, Mehmet Adigul, Ahmet Ergin Capar (2016). Comparison of the effects of two different dose algorithms in cardiac dose parameters for hodgkin lymphoma patients receiving mediastinal radiotheraphy. Medical Science and Discovery, 3(8), 301-4. https://europub.co.uk./articles/-A-520527