COMPARISON OF TITANIUM SCREW WITH POLYESTER BAND WITH CLAMP (LOTUS) AND RIGID TITANIUM TRANSVERSE BINDER SYSTEM USING THE FINITE ELEMENT ANALYSIS

Journal Title: Journal of Turkish Spinal Surgery - Year 2017, Vol 28, Issue 2

Abstract

Objective: There are many studies in the literature for posterior spinal instrumentations. In this study, we compared a titanium screw with a polyester band with a clamp (LOTUS) and a rigid titanium transverse binder system, which are used in the lower lumbar region and to examine the strength and superiority of the systems against each other with the finite element (FE) analysis. Material and Methods: A Ti6Al4V grade 5 titanium biocompatible alloy support for a pediclebased posterior stabilization system and a polyethylene band support for a pedicle-based posterior stabilization system were compared as testing material. Results: Range of motion was decreased by 95.8 % when a pedicle-based stabilization system was used at L4–L5. Range of motion was decreased further, about 1%, when the polymer band was used in conjunction with a posterior stabilization system in axial rotation. Conclusion: Similar results were observed when a titanium transverse connector was used. In light of the results of all finite element analyses, neither the titanium screws with a polyester band with a clamp (LOTUS) nor the rigid titanium transverse binder system has a significant superiority over the other. Equivalent results in the limitation of movement and rigidity allow the use of these systems in short-segment posterior spinal instrumentation with the same indications.

Authors and Affiliations

Birol ÖZKAL, Can YALDIZ, Mete KARATAY, Haydar ÇELİK, Deniz KARABULUT, Iman ZAFARPARANDAH, Onur YAMAN, İhsan SOLAROĞLU, Fahir ÖZER

Keywords

Related Articles

SELECTIVE THORACIC FUSION IN ADOLESCENT IDIOPATHIC SCOLIOSIS WITH LENKE TYPE 1C, 3C OR KING TYPE 2 LUMBAR CURVES OF MORE THAN 50 DEGREES IN MAGNITUDE

The operative goals of surgery in adolescent idiopathic scoliosis are to prevent progression while providing safe and optimal coronal correction, sagittal alignment, and axial derotation. The aim of this retrospective cl...

SURGICAL APPROACH IN T4N0M0 (VERTEBRAL INVOLVEMENT) LUNG CANCER

Approximately five percent of the lung cancers involve the chest wall and spine by direct extension and remain localized at the time of diagnosis. T4 lesions invading the vertebra are considered inoperable. We reviewed a...

THE EFFECTS OF AGE ON CERVICAL MYELOPATHY

22 cases diagnosed with cervical magnetic resonance imaging (MRI) and operated due to myelopathy between 1990-1996 were evaluated in this study. These cases were divided into two groups as younger 60 (Group 1-10 cases) a...

NON-SPECIFIC (PYOGENIC) SPINAL INFECTIONS

Omurga enfeksiyonlar›, vertebra cisimlerini, intervertebral diskleri, spinal kanal› ve paravertebral yumuflak dokular› etkiler. Çok s›k görülmemekle beraber tan› koymadaki zorluklar tan›n›n gecikmesine ve çok ciddi...

VOLUMETRIC ANALYSIS OF VERTEBRAL HEMANGIOMAS: A RETROSPECTIVE STUDY

Purpose: This study was carried out to analyze the volume and localization of vertebral hemangiomas at the T12–L5 levels by MRI in patients with lower back pain. Methods: Thoracic-lumbar MRIs were examined retrosp...

Download PDF file
  • EP ID EP676949
  • DOI -
  • Views 124
  • Downloads 0

How To Cite

Birol ÖZKAL, Can YALDIZ, Mete KARATAY, Haydar ÇELİK, Deniz KARABULUT, Iman ZAFARPARANDAH, Onur YAMAN, İhsan SOLAROĞLU, Fahir ÖZER (2017). COMPARISON OF TITANIUM SCREW WITH POLYESTER BAND WITH CLAMP (LOTUS) AND RIGID TITANIUM TRANSVERSE BINDER SYSTEM USING THE FINITE ELEMENT ANALYSIS. Journal of Turkish Spinal Surgery, 28(2), -. https://europub.co.uk./articles/-A-676949