Comparison of total image quality in Tissue Harmonic Imaging as compared to conventional ultrasound technique in abdominal and pelvic ultrasonography
Journal Title: Journal of Medical Science And clinical Research - Year 2018, Vol 6, Issue 4
Abstract
The study was conducted at the Department of Radiodiagnosis and Imaging, Army Hospital (Research & Referral), Delhi Cantt on 200 patients (114 females, 86 males) with varying age and BMI (Body Mass Index) from year 2005 to 2009. Abdominal and pelvic sonography was done on grey scale using HDI 5000 (Philips/ATL) system. This equipment awarded a U.S. patent for Tissue Harmonic Imaging (THI). The study was done using broadband curvilinear 2 to 5 MHz (C 5-2) transducer. This transducer can be used for both conventional B-mode and tissue harmonic imaging. The equipment does not allow to manual selection of the frequencies. (12).The patients were 6 hours fasting prior to all examinations. These were performed by the same operator in order to achieve standardized results. Before the study was embarked standardization of the images was done with 10 normal subjects. Correlation was done for BMI of the study population and was found that grater percentage of lesions were seen better THI in patients having BMI >25.The p value was < 0.05 (significant). Out of the 258 positive findings assessed for total image quality in THI in comparison to CUSS the p value was <0.001 (significant). Hence the study concludes that THI is significantly better in demonstrating, defining, characterizing and eliminating the various image artifacts THI is hence recommended for routine screening and study for abdominal and pelvic organs in both males and females of varying BMI and body habitus.
Authors and Affiliations
Dr Rajat Kumar Sharma
Perianal Fibroma: A Rare Encounter!! Case Report with Review of Literature
Fibroma of ano rectal region is very rare. It may arise from a hypertrophied papilla or by fibrous infiltration of a large prolapsing internal haemorrhoid, generally as a result of repeated attacks of thrombosis and stra...
A comparative ultrasonic study of prostate gland
Background: BPH is a common disorder among elderly males. There is a strong suspicion that the prevalence of BPH is higher than has been reported in clinical retrospective and necroscopy studies. For its deep topographic...
Significance of Adenosine Deaminase Levels in Diagnosis of Pleural Effusion
The present study was carried out in 71 patients in a tertiary care center with an aim to study the correlation of results of ADA test and lymphocyte proportion with clinical / radiological findings and results of other...
Laterally Displaced Flap – A Case Report
Gingival recession may cause the patient to feel esthetic discomfort and dentin hypersensitivity. Obtaining predictable and esthetic root coverage has become an important goal of a periodontal surgeon. Even though there...
Detection of Vancomycin susceptibility including h-VISA among Methicillin resistant Staphylococcus aureus and Staphylococcus species isolated from orthopaedic device associated infections in a tertiary care hospital
Globally, Staphylococcus aureus is the major causative organism for medical device associated infections. Of this, the proportion of Methicillin resistant Staphylococcus aureus (MRSA) has worldwide for the last two decad...