Compliance of Some Quality Control Parameters of Diagnostic Xray Equipment in Three Selected Tertiary Hospitals in South East, Nigeria to a known standard.
Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2018, Vol 17, Issue 10
Abstract
Introduction: Periodic monitoring of X-ray equipment quality control parameters is very important to ensure precision and accuracy of radiographic tests. Aim: The aim of this study is to assess the compliance of some quality control (QC) parameters of some conventional X-ray equipment to a known standard. Settings and Design: Setting was in Nigeria and a cross sectional design was used. Method and Material: Material used was a non-invasive digital multifunctional detector meter (MDM). Three facilities were selected from a university teaching hospital. Measurement of KVp, mAs and the exposure time accuracy was performed using MDM that incorporates computer output. The MDM was positioned at the center of the collimated beam axis with a Source to Image Distance (SID) of one meter. Eight different mAs, exposure times and KVp stations were selected and measured in each teaching hospital. Statistical Analysis: SPSS was used and statistical tools used was one way ANOVA The result obtained showed that the magnitude of deviation in KVp accuracy ranged from 0.01 to 6.07 % in all the four machines checked while the magnitude of deviation in mAs accuracy ranged from 0.00 to 19.20 %. In a similar way, exposure time accuracy deviated from 0.01 to 12.32 %. Conclusion: The study revealed that only one out of the four X-ray units at the teaching hospital in the Southern-Eastern part of Nigeria failed exposure time, mAs and KVp accuracy compliance test. K
Authors and Affiliations
Nnamdi F. Nworah, Christian C. Nzotta, Uche H. Chiegwu, Michael E. Aronu, Emmanuel O. Oyekunle
Evaluation of Orbital and Ocular Lesions on Sonography
Loss of sight ranks second or third in people’s perceptions after the most feared conditions of cognitive loss or cancer, hence importance for early diagnosis and treatment is required in which radiology plays important...
To Compare The Efficacy of Thiopentone with Laryngeal Spray of 4% Lidocaine and Propofol for Laryngeal Mask Airway (LMA) Insertion.
Introduction: Airway management is one of the most important skills in the field of anesthesiology and inability to secure the airway can lead to catastrophic results. Before 1990, only the face mask and the endotracheal...
Epidermodysplasia Verruciformis in A HIV Patient –A Rare Case Report
Epidermodysplasia Verruciformis (EDV), is a rare autosomal recessive genodermatosis with cases linked to chromosome X, and attributed to infection by specific types of Human Papilloma Virus (HPV) in immunologically defic...
TB or Not TB- That is the Question: Misdiagnosis of Spinal Metastasis As Tuberculosis Spine
Introduction: Due to the increased prevelance of Tubeculosis and the practical acceptance of Trial Anti Tubercular Therapy (ATT), it is the first diagnosis that comes to our mind while anaplastic conditions are our last...
Correlation between MRI Findings and Arthroscopic Findings in Internal Degeneration of Knee
Aim: The aim of this study is to compare the MRI findings with arthroscopy findings in internal derangement of knee. Material and methods: 124 patients of different age group and sex with internal derangement of knee (ID...