Confirmation of endotracheal tube placement using disposable fiberoptic bronchoscopy in the emergent setting

Journal Title: World Journal of Emergency Medicine - Year 2019, Vol 10, Issue 4

Abstract

BACKGROUND: Patients intubated in the prehospital setting require quick and definitive confirmation of endotracheal (ET) tube placement upon arrival to the emergency department (ED). Direct and adjunct strategies exist, but each has limitations and there is no definitive gold standard. The utility of bronchoscopy in ED intubation has been studied, but scant literature exists on its use for ET tube confirmation. This study aims to assess effectiveness, ease and speed with which ET tube placement can be confirmed with disposable fiberoptic bronchoscopy. METHODS: Emergency medicine residents recruited from a 3-year urban residency program received 5 minutes of active learning on a simulation mannequin using a disposable, flexible Ambu aScope interfaced with a monitor. With residents blinded, the researcher randomly placed the ET tube in the trachea, esophagus or right mainstem. Residents identified ET tube position by threading the bronchoscope through the tube and viewing distal anatomy. Each resident underwent 4 trials. Accuracy, speed and perceptions of difficulty were measured. RESULTS: Residents accurately identified the location of the ET tube in 88 out of 92 trials (95.7%). The median time-to-guess was 7.0 seconds, IQR (5.0–10.0). Average perceived difficulty was 1.6 on a scale from 1–5 (1 being very easy and 5 being very difficult). No tubes were damaged or dislodged. CONCLUSION: While simulation cannot completely replicate the live experience, fiberoptic bronchoscopy appears to be a quick and accurate method for ET tube confirmation. Further studies directly comparing this novel approach to established practices on actual patients are warranted.

Authors and Affiliations

Keywords

Related Articles

The risk of wound infection after simple hand laceration

BACKGROUND: This prospective observational study aimed to determine the infection rate of simple hand laceration (SHL), and to compare infection rates between patients who were prescribed antibiotics and those who were n...

Images in emergency medicine: giant ascending aortic aneurysm dissection with hemopericardium

BACKGROUND: Acute chest pain represents a common presentation at emergency department. Aortic dissection in young patients, however, is fortunately rare. METHODS: We report a case of giant ascending aortic aneurysm with...

Differential diagnoses of magnetic resonance imaging for suspected acute appendicitis in pregnant patients

BACKGROUND: Accurate and timely diagnosis of acute surgical disease in pregnant patient is challenging. Although magnetic resonance imaging (MRI) is the most accurate modality to diagnose acute appendicitis in pregnant p...

Epinephrine in out-of-hospital cardiac arrest: A critical review

BACKGROUND: Epinephrine is recommended in advanced cardiac life support guidelines for use in adult cardiac arrest, and has been used in cardiopulmonary resuscitation since 1896. Yet, despite its long time use and incorp...

Short lessons in basic life support improve self-assurance in performing cardiopulmonary resuscitation

BACKGROUND: There are several reasons why resuscitation measures may lead to inferior results: difficulties in team building, delayed realization of the emergency and interruption of chest compression. This study investi...

Download PDF file
  • EP ID EP630628
  • DOI 10.5847/wjem.j.1920–8642.2019.04.003
  • Views 100
  • Downloads 0

How To Cite

(2019). Confirmation of endotracheal tube placement using disposable fiberoptic bronchoscopy in the emergent setting. World Journal of Emergency Medicine, 10(4), 210-214. https://europub.co.uk./articles/-A-630628