Contamination Measurements of Patient’s Lead-Insulated Rooms After I-131 and LU-177 PSMA Treatment via Sweeping Test

Journal Title: Cumhuriyet Science journal - Year 2018, Vol 39, Issue 2

Abstract

I-131 and Lu-177 PSMA radionuclides have been widely used in the field of nuclear medicine to treat thyroid cancer for many years. In this treatment, the patients whose dose rate measurements are less than 3 mR/h are generally discharged from the lead-insulated rooms where they are hospitalized. The aim of our study is to evaluate the contamination measurements of these rooms after I-131 and LU-177 PSMA treatment and to ensure radiation safety. A sweeping test was carried out by using Whatman papers (10x10 cm2 in size) to take samples from designated areas of these rooms in which three patients were treated with Lu-177 PSMA and four patients were treated with the I-131 radionuclide. Whatman papers are placed inside different tubes to prevent external contamination. Afterward, counting procedure was taken to the tubes for one minute by using the gamma counter which has different calibration factors both for Lu-177 and I-131 radionuclides. For the background extraction, one-minute counting test was applied to one of the Whatman papers that were not used for sweeping and background value was then obtained. It was statistically understood that the highest contamination rate was observed on the surface of toilet potteries in each room. As a result, ventilation of the room, meticulous cleaning of contaminated areas and the sweeping test must be implemented in each room where the patients are treated with radionuclides before the treatment of other patients.

Authors and Affiliations

Tuğba DEMİRBAY, Kübra HARMAN, Mustafa DEMİR

Keywords

Related Articles

Experimental Investigation of Cooling - Heating Performance of Counter Flow Ranque-Hilsch Vortex Tubes Having Different Length Diameter Ratio

In this study, a counter flow Ranque-Hilsch Vortex Tube having 6 nozzles was experimentally investigated. The vortex tube’s Length – diameter (L/D) ratios were 10 and 12.5 and compressed air was used as working fluid and...

The Forward Kinematics of Rolling Contact of Spacelike Surfaces in Lorentzian 3-Space

In this paper, we investigate the forward kinematics of spin-rolling motion without sliding of one spacelike surface on another spacelike surface along the spacelike contact trajectory curves of the surfaces in Lorentzia...

On a Relation Between Twistors and Killing Spinors

Inspiring from the consequence of constructing conformal Killing-Yano forms out of Killing-Yano forms and closed conformal Killing-Yano forms, this work includes a method for building up twistors from Killing spinors whi...

Archimedean Copula Estimation Parameter with Kendall Distribution Function

In the literature, up to now, it is common that for Gumbel, Clayton and Frank calculated Kendall Distribution function  and to the extent those applications have been made. In this paper, we made Kendall Distribution fun...

Comparison of Spectral Classification Methods in Water Quality

Today, water quality and water pollution can be detected using remote sensing and its terrestrial components. Remote sensing does not only provide a quick solution to detect water quality and pollution, but it could also...

Download PDF file
  • EP ID EP488360
  • DOI 10.17776/csj.359939
  • Views 57
  • Downloads 0

How To Cite

Tuğba DEMİRBAY, Kübra HARMAN, Mustafa DEMİR (2018). Contamination Measurements of Patient’s Lead-Insulated Rooms After I-131 and LU-177 PSMA Treatment via Sweeping Test. Cumhuriyet Science journal, 39(2), 431-438. https://europub.co.uk./articles/-A-488360