Contingency Analysis of the Nigeria 330kv Post-Reform Integrated Power System Using Power World Simulator

Journal Title: ASIAN JOURNAL OF NATURAL & APPLIED SCIENCES - Year 2015, Vol 4, Issue 2

Abstract

With the Nigeria Power Sector going through reforms, it is very important to be able to predict the extent of violations that can occur in the network in the event of unprecedented contingencies. This is usually achieved through contingency analysis of the network in order to make for adequate provision of infrastructure to ensure system security in event of such contingencies. In this paper, single line contingency analysis for the Nigeria 330kv post-reform grid to determine violations in the network due to the individual contingencies were considered using power world simulator. The simulation result indicates that with generator contingency at mambilla, there were six bus violations with a maximum per unit voltage of 1.166. There were also seven bus violations for Jos-Gombe and Damaturu-Mambilla line contingencies with minimum per unit voltages of 0.921 and 0.399 respectively.

Authors and Affiliations

O. J. , K. Inyama, G. C. Ononiwu

Keywords

Related Articles

IONOSPHERIC ANOMALY FROM HUGE GAS EXPLOSION IN KAOHSIUNG CITY IN TAIWAN ON 31 JULY 2014

This paper used two-dimensional Principal Component Analysis (2DPCA) to determine total electron content (TEC) respond in the ionosphere for the huge gas explosion in Kaohsiung, Taiwan at 15: 59 (UT) on 31 July 2014. Res...

FORENSIC TOOLS FOR INVESTIGATING CYBER CRIMES

Nowadays in the developed countries, most of the governmental and private organizations use technology for running their activities. Using Internet, is becoming part of daily routine for running the organizations. Howeve...

ANTIOXIDANT AND ANTI-LIPIDPEROXIDATION POTENTIALS OF THE ETHYLACETATE AND CHLOROFORM EXTRACTS OF BASELLA ALBA LEAVES

 The search for antioxidants in various plants fractions became pertinent since they limit the oxidation of macro molecule by free radical that leads to cellular oxidative damage implicated in several chroni...

 THE IMPACT OF TRADITIONAL MEDICINE ON IRANIAN CUISINE INGREDIENTS

 In far past, Iranian cuisines and traditional medicine were linked together; thus practitioners mentioned the name of many different cuisines along with their benefits and risks in their books and looked up on...

Download PDF file
  • EP ID EP159251
  • DOI -
  • Views 104
  • Downloads 0

How To Cite

O. J. , K. Inyama, G. C. Ononiwu (2015). Contingency Analysis of the Nigeria 330kv Post-Reform Integrated Power System Using Power World Simulator. ASIAN JOURNAL OF NATURAL & APPLIED SCIENCES, 4(2), 70-85. https://europub.co.uk./articles/-A-159251