Correlation between symptoms and sign of drug users with dry eye

Journal Title: Guoji Yanke Zazhi - Year 2018, Vol 18, Issue 12

Abstract

AIM: To investigate the correlation between symptoms and sign of drug users with dry eye. <p>METHODS: Eighty-seven patients(87 eyes)with dry eye syndrome who were abstained from a compulsory rehabilitation center in Yangpu District of Shanghai from October 2017 to February 2018 were selected as test group. And 90 eyes of 90 patients with non-dry eye syndrome who were abstained from the same center during the same period were selected as control group. All subjects were selected for the right eye. All the patients were analyzed including dry eye questionnaire-5, ocular surface disease index(OSDI)questionnaire survey, symptoms, tear height test, break-up time test, sodium fluorescein staining test, tear osmotic pressure, Schirmer Ⅰ test and Meibomian gland function tests. Pearson and Spearman correlations were used to analyze the relationship between symptoms and signs of drug users with dry eye. <p>RESULTS: Both the DEQ-5 questionnaire and the OSDI questionnaire scores were negatively correlated with BUT values(<i>r</i>=-0.791, -0.849, <i>P</i><0.01), and were also positively correlated with corneal fluorescein sodium staining(DEQ-5: <i>r</i>=0.652, <i>P</i><0.01; OSDI: <i>r</i>=0.571, <i>P</i><0.05). The scores of DEQ-5 questionnaire and OSDI questionnaire were not significantly correlated with tear height, tear osmotic pressure, Schirmer Ⅰ test, and Meibomian gland functional score. Fatigue, dryness, and visual acuity were the three most common symptoms(69.0%, 63.2%, 55.2%, respectively). The negative correlation was shown between photophobia and tear height(<i>r</i>=-0.218, <i>P</i>=0.023). Dryness, fatigue, pain/sting, visual acuity were also negatively correlated with BUT(<i>r</i>=-0.057,-0.197, -0.053, -0.068, <i>P</i><0.05). The positive correlation was shown between dryness, fatigue, visual acuity and FL(<i>r</i>=0.169, 0.201, 0.226, <i>P</i><0.05), tearing and tear osmotic pressure(<i>r</i>=0.315, <i>P</i>=0.013), dryness and Schiemer Ⅰ(<i>r</i>=0.324, <i>P</i>=0.043). Visual acuity was positively correlated with meibomian gland function(<i>r</i>=0.227, <i>P</i>=0.011). The difference in tear height, corneal fluorescein sodium staining, and tear osmotic pressure were statistically significant between dry eye patients and normal group(<i>P</i><0.05). The differences in BUT, Schirmer Ⅰ test and meibomian gland function were not statistically significant(<i>P</i>>0.05). <p>CONCLUSION: The clinical symptoms of dry eye in drug users are not obvious, and their correlation with the test results is poor. Clinicians should pay attention to the medical history inquiry, physical examination, and the refinement and individualization of diagnosis.

Authors and Affiliations

Jian-Qun Ha

Keywords

Related Articles

Effect on enophthalmos between different edge point repairment after orbital wall fracture repair surgery

AIM: To investigate the importance between several edge points repair through enophthalmos study after orbital wall fracture repair surgery. <p>METHODS: The date of 23 eyes of 23 cases with medial-inferior orbital wall f...

Early detection using dual-specific probe technique for genetic mutation of congenital cataract lens protein

AIM: To screen congenital cataract in the early stage using dual-specific probe technique composed of DNA hybridization and chromogenic probe. <p>METHODS: The mRNA was isolated from venous blood of 14 congenital cataract...

Effect of different incision phacoemulsification on corneal endothelial function and tear film function in senile cataract patients

AIM: To explore the effect of different incision phacoemulsification on corneal endothelial function and tear film function in senile cataract(SC)patients. <p>METHODS: Totally 90 SC patients(90 eyes)admitted to our hospi...

Scleral buckling with chandelier illumination system in rhegmatogenous retinal detachment surgery: a large case series

AIM: To evaluate advantages of chandelier illumination system during scleral buckling(SB)procedures for rhegmatogenous retinal detachment(RRD)surgery. <p>METHODS: In this comparative, retrospective study, data of 72 eyes...

Clinical significance of changes of chemokine MIP-1 alpha and MIP-1 beta levels in peripheral blood of patients with diabetic retinopathy

AIM: To observe the changes of chemokine macrophage inflammatory protein(MIP-1α)and MIP-1β in peripheral blood of patients with diabetic retinopathy and to analyze its clinical significance. <p>METHODS: The patients with...

Download PDF file
  • EP ID EP501609
  • DOI 10.3980/j.issn.1672-5123.2018.12.22
  • Views 125
  • Downloads 0

How To Cite

Jian-Qun Ha (2018). Correlation between symptoms and sign of drug users with dry eye. Guoji Yanke Zazhi, 18(12), -. https://europub.co.uk./articles/-A-501609