Correlation of Serum Creatinine Based Calculation of Glomerular Filtration Rate with Measured Radio Isotope Glomerular Filtration Rate in Healthy Individuals and Chronic Kidney Disease Patients
Journal Title: International Journal of Trend in Scientific Research and Development - Year 2021, Vol 5, Issue 2
Abstract
INTRODUCTION GFR is best index of kidney function in health and disease and accurate values are needed for optimal decision making in clinical settings. Estimated GFR eGFR based on serum creatinine is first line test of kidney function. CG formula is creatinine based equation and widely applied. Tc99m DTPA Diethylene Triamine Penta Acetic acid is the most commonly used radiopharmaceutical for GFR studies. The Gate method has been most common in the routine setting. AIM AND OBJECTIVES To study correlation of serum creatinine based calculation of GFR with measured ratio isotope GFR in healthy individuals and CKD patients. To assess the accuracy of GFR as calculated by CG GFR formulae using serum creatinine against measured RI GFR Tc 99m DTPA . METHODS This study observational study, which is done in department of medicine and department of nuclear medicine at Army Hospital RandR, Delhi Cantt in CKD and healthy individuals. Our study includes a total of 100 subjects with varying renal functions which includes 50 healthy individual and 50 CKD patients. RESULTS In this study it has been observed that in healthy group CG GFR has weak correlation with DTPA GFR r = 0.104 with p 0.471 . In study it has been observed that in CKD patients CG GFR significantly correlate with DTPA. r = 0.614 with a p 0.001 . In category 79 subjects was selected with creatinine value between 0.7 to 3.7 mg dl. In this group it has been observed that CG GFR significantly correlate with DTPA. r = 0.815 with P 0.001 . In healthy subjects mean eGFR by CGGFR is 104.26 ± 31.09 range 65.4 176.2 ml min 1.73m2, whereas mean mGFR by DTPA is 92.15 ± 17.85 range 49.9 131.8 ml min 1.73m2. In healthy subjects eGFR by CGGFR overestimate the mGFR by DTPA GFR. On the other hand there is poor correlation between eGFR by formula with mGFR. In CKD subjects mean eGFR by CG GFR is 31.10 ± 14.51 range 4.74 to 57.9 ml min 1.73m2, whereas mean mGFR by DTPA is 40.06 ± 13.64 range 10.4 to 84.19 ml min 1.73 m2. In these subjects eGFR by GCGFR underestimate the mGFR by DTPA. On the other hand there is positive significant correlation p 0.001 between eGFR by both formula with mGFR. We have also observed that subjects with creatinine value between 0.7 to 3.5 mg dl, irrespective of their disease status Healthy and CKD subjects has significant positive correlation between eGFR CG GFR with mGFR DPTA p value 0.001 . It signifies that with extremes of creatinine either very low or very high value eGFR doesn’t correlate with mGFR. CONCLUSION AND RECOOMANDATIONS In conclusion, the modified Gates method is undoubtedly an important method in unilateral renal function measurement. But our results implied that its performance in total GFR estimation was not better than the CG equations. Lt Col (Dr.) Rahul Soni | Dr. Jayita Debnath "Correlation of Serum Creatinine Based Calculation of Glomerular Filtration Rate with Measured Radio Isotope Glomerular Filtration Rate in Healthy Individuals and Chronic Kidney Disease Patients" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-2 , February 2021, URL: https://www.ijtsrd.com/papers/ijtsrd38443.pdf Paper Url: https://www.ijtsrd.com/medicine/other/38443/correlation-of-serum-creatinine-based-calculation-of-glomerular-filtration-rate-with-measured-radio-isotope-glomerular-filtration-rate-in-healthy-individuals-and-chronic-kidney-disease-patients/lt-col-dr-rahul-soni
Authors and Affiliations
Lt Col (Dr. ) Rahul Soni | Dr. Jayita Debnath
Review on Osmotically Controlled Drug Delivery System
Oral Osmotic Drug Delivery System is the new found delivery system of Novel Drug Delivery System. Oral Osmotic Drug Delivery System works on the principle of Osmosis and Osmotic Pressure for the pre planned and correct d...
Food Safety Practices among Street Food Vendors in Diplo, Sindh, Pakistan
Diplo town lack food industry, market places coined with food streets. Vendors role to ascertain public health by conserving safety of food chain. Food can be contaminated like improper processing operations, lack of per...
Global Food Fraud A Primer
As markets grow from local to global, food supply chains become complex distribution systems and pose the challenge of safeguarding our food supply. Food fraud is an emerging global problem with wide range of economic, s...
FTIR Spectra of Ni (H-dmg)2 Hydrogen Bonded With Six Dyes
Here the one-dimensional semiconductor namely bis (dimethyiglyoximato) Ni?? is hydrogen bonded with 6 highly polarizable dyes which are Para red, Congo red, Direct red, Bismark brown, Evans blue and Trypan blue. The hydr...
Legal Analysis in Relation to Authorised Banking Operations within the BEAC Zone
Banks are catalysts to economic development. Any stable economy will depend upon how solid its banking system operates. Due to this, there is the need for good and effective reforms. Thus, in 1964, the Custom Union of Ce...