Correlation of ultrasound guided measurement of inferior vena cava diameter to central venous pressure to assess the volume status of intensive care unit patients

Journal Title: Indian Journal of Clinical Anaesthesia - Year 2017, Vol 4, Issue 1

Abstract

Background: Assessment of intravascular volume status is an essential parameter for the diagnosis and management of critically-ill patients. In order to assess the intravascular volume status noninvasively, we conducted a study to to find the correlation, if any, between sonographic IVC collapsibility index and Central Venous Pressure to assess the volume status in ICU patients. Methods: The Institutional Ethics Committee approval was obtained. 60 spontaneously breathing post-operative patients with a functioning central venous catheter were recruited for this study. The distal port of the catheter was connected to a pressure transducer and the pressure displayed on the monitor in mmHg was noted. Simultaneously the IVC diameters during end inspiration and end expiration were measured in the longitudinal and transverse orientations using the M-mode of the ultrasound machine. The Collapsibility Index was calculated from the IVC diameters. Collapsibility Index? 50% suggested hypovolemia and Collapsibility Index <50% suggested euvolemia or hypervolemia. This was compared with the measured Central Venous Pressure to find the correlation between the two. Additionally the change in IVC diameter with Central Venous Pressure was observed. The IVC Collapsibility Index for longitudinal and transverse orientations were calculated separately and they were compared with each other to find which among them correlated the best with the Central Venous Pressure. Results: In our study the IVC Collapsibility Index correlated well with the Central Venous Pressure. The sensitivity and specificity of IVC Collapsibility to Central Venous Pressure were also found to be statistically significant. The change in IVC diameters were also found to be statistically significant when compared to Central Venous Pressure. The sensitivity of the IVC Collapsibility Index in the longitudinal orientation was much better than that of the transverse orientation to detect low CVP. Conclusion: IVC Collapsibility Index can be used as an alternative to CVP measurement to guide us in the fluid management of patients in the ICU.

Authors and Affiliations

Placid Siroraj, Sunder Panneerselvam, CR Saravannan

Keywords

Related Articles

Combination of buprenorphine with hyperbaric bupivacaine administered either as a mixture or sequentially for spinal anaesthesia for caesarean section

Introduction: Density of local anesthetic is an important determining factor for the distribution, duration and degree of the block achieved in spinal anaesthesia, with small changes influencing its distribution. Mixing...

Comparative study of caudal Ropivacaine with ropivacaine & Ketamine for postoperative analgesia in paediatric patients

Objective: Objective of this study was to determine the efficacy of caudal Ketamine added to ropivacaine in providing postoperative analgesia in pediatric age group. Materials and Method: This was a prospective randomize...

Comparison of recovery profile of desflurane and sevoflurane in dental surgeries

Aim: Is to find the recovery profile of desflurane anaesthesia to sevoflurane anaesthesia during dental surgeries. Settings and Design: Single Blind Randomized controlled trial. Methods: Forty ASA I and II patients under...

Ultrasound versus nerve stimulation technique for interscalene brachial plexus block: A randomized controlled trial

Introduction and Aims: Peripheral nerve block techniques have evolved over time with the advent of peripheral nerve stimulator and ultrasonography. We intend to compare these two techniques in this study with respect to...

Infantile hypertrophic pyloric stenosis - does optimal pre-operative stabilisation enhance recovery: a retrospective study

Introduction: Infantile hypertrophic pyloric stenosis is a pathological condition of early infancy which poses many challenges to both treating surgeons and anaesthesiologists. Correction of acid base imbalance and dysel...

Download PDF file
  • EP ID EP311610
  • DOI 10.18231/2394-4994.2017.0024
  • Views 82
  • Downloads 0

How To Cite

Placid Siroraj, Sunder Panneerselvam, CR Saravannan (2017). Correlation of ultrasound guided measurement of inferior vena cava diameter to central venous pressure to assess the volume status of intensive care unit patients. Indian Journal of Clinical Anaesthesia, 4(1), 112-117. https://europub.co.uk./articles/-A-311610