Custom Ocular Prosthesis Fitting Following Evisceration: Staphyloma Vs. Non-staphyloma cases

Journal Title: IP International Journal of Ocular Oncology and Oculoplasty - Year 2016, Vol 2, Issue 1

Abstract

Purpose: To assess and compare the prosthetic eye fitting in the patients undergoing evisceration with implant in staphyloma vs. non-staphyloma cases. Methods: It was a retrospective, comparative and interventional study. Patients who underwent evisceration with silicone orbital implant placement, and fitted with custom ocular prosthesis between August 2006 and April 2007 were included. Based on the indication for surgery, the patients were grouped under staphyloma and other conditions. Eyelid and socket abnormalities, and additional modifications undertaken to correct these abnormalities during fabrication of custom prosthesis were assessed, and compared between the two groups. Independent samples T-test was used for statistical analysis. Results: In the staphyloma group, 9 of 16 (56.3%) had ptosis (6), eyelid retraction (2), and deep superior sulcus (1) needing prosthesis modification. In contrast, the patients who underwent evisceration for other conditions, only 2 of 27 (7.4%) required modifications for lid sag. Statistical analysis showed significantly greater number of patients needed modifications in staphyloma group as compared to non-staphyloma group (P=0.001). Implant size, and duration between the date of surgery and the prosthesis fitting were compared between two groups, which showed no statistically significant difference (P=0.096 and P=0.108 respectively). Conclusion: The patients with staphyloma undergoing evisceration with implant can have cosmetically concerning eyelid abnormalities, most commonly ptosis that may need attention during fabrication of the prosthetic eye. These eyelid abnormalities could be due to long standing effect of staphyloma, possibly due to levator disinsertion, dehiscence or stretching; or due to insufficient volume replacement by an orbital implant

Authors and Affiliations

Deepa Diddi Raizada, Kuldeep Raizada

Keywords

Related Articles

Etiology and pattern of orbital fractures in a teaching hospital

Purpose: To explore the etiological factors and pattern of orbital injuries in patients of trauma. Materials and Method: A prospective case series of 176 patients of orbital trauma diagnosed by computerized tomography. A...

A prospective comparative analysis of clinical versus histopathological diagnosis following excision biopsy of ocular lesions

Biopsy is surgical removal of a tissue specimen for histopathological evaluation of the clinical lesion to arrive at a confirmatory diagnosis. Most of the ocular and extra ocular lesions are diagnosed by a good history a...

Assessment of body mass index (BMI) as an independent factor affecting intra ocular pressure (IOP)

To analyze a correlation between obesity and intraocular pressure IOP in Indian cohort To find a possible correlation between body mass index BMI and intra ocular pressure IOP To study whether BMI can be an independent f...

Prospective analyses of peribulbar block anaesthesia in intraocular surgery using 13 mm long 26 gauge needle

Intraocular surgeries are usually done under local anaesthesia using either topical anaesthetic eye drops or using blocks like retrobulbar, peribulbar or a sub-tenon’s injection of local anaesthetic agents. The aim of th...

Myoepithelioma of lacrimal gland: A rare entity

Myoepithelioma of lacrimal gland, an extremely rare monomorphic adenoma, has been reported only 7 times to the best of our knowledge. We report a case of 62 years old female who presented with painless proptosis of the l...

Download PDF file
  • EP ID EP243182
  • DOI -
  • Views 110
  • Downloads 0

How To Cite

Deepa Diddi Raizada, Kuldeep Raizada (2016). Custom Ocular Prosthesis Fitting Following Evisceration: Staphyloma Vs. Non-staphyloma cases. IP International Journal of Ocular Oncology and Oculoplasty, 2(1), 42-47. https://europub.co.uk./articles/-A-243182