D-dimer Levels are not a Good Marker for Venous Thromboembolism in Patients Before and After Total Hip Replacement

Journal Title: Ortopedia Traumatologia Rehabilitacja - Year 2018, Vol 20, Issue 5

Abstract

Background. Total hip replacement activates the coagulation and fibrinolysis systems. The aim of this paper is to describe the concentrations of these proteins following elective total hip replacement. Material and methods. This prospective laboratory study enrolled 30 patients (including 18 women) who had been qualified for primary total hip replacement due to idiopathic osteoarthritis. Mean age was 70 years (range: 45-86 years). All patients received venous thromboembolism (VTE) prophylaxis according to the current guidelines (enoxaparin 40 mg SC s.i.d. from the day of the procedure). An immunoenzymatic assay (ACL TOP 500 CTS analyser, Beckman Coulter, Brea, CA, USA) was used to determine D-dimer levels before the surgical procedure, 6 hours after the procedure, and on the 2nd, 4th, and 6th post-operative day. Results. No patients showed signs and symptoms of VTE during the hospital stay. The mean D-dimer level before the procedure was 1 mg/ml, with a highest mean value of 11.8 mg/ml at 6 hours after the procedure; the levels would then decrease but would remain above the normal range for 6 days after surgery. Elevated baseline D-dimer levels (>0.5 mg/ml) were found in 80% of the study patients. Conclusions. 1. D-dimers act like acute phase proteins, with levels increasing several-fold following total hip repla­cement. 2. D-dimer levels cannot be used to diagnose venous thromboembolism even before the procedure and hospi­talisation in patients with idiopathic coxarthrosis and no clinical manifestations of thrombosis.<br/><br/>

Authors and Affiliations

Marcin K. Waśko, Marta Burbul, Krzysztof Gawroński, Artur Pepłoński

Keywords

Related Articles

<br /> Potential value of three-dimensional ultrasonography in diagnosing muscle injuries in comparison to two-dimensional examination – preliminary results<br />

Two-dimensional ultrasonography (2D-US) has become a widely used and accepted diagnostic tool in musculoskeletal disorders. Its utility in the evaluation of muscle injury and pathology is generally recognised. In contras...

Ocena wyników operacyjnego leczenia zespołu kanału nadgarstka metodą endoskopową z wykorzystaniem jednego dostępu

Wstęp. Wyniki operacyjnego leczenia zespołu kanału nadgarstka (zkn) zależą od wielu czynników, do których zalicza się wiek chorych oraz stopień zaawansowania choroby. Celem pracy było zbadanie wpływu wieku oraz stopnia z...

The value of computed tomography with 3D reconstruction for the diagnosis of pelvic and spine fractures following a sports injury – a case report.

The paper presents the case of a young snowboarder injured after falling down on a hill slope. Pelvis and spine computed tomography with 3D reconstruction visualised fractures not visible on standard radiographs. Not all...

Zastosowanie kostnych przeszczepów uszypułowanych w leczeniu stawów rzekomych kości łódeczkowatej

Celem pracy było przedstawienie aktualnie stosowanych metod leczenia stawów rzekomych kości łódeczkowatej z zastosowaniem kostnych przeszczepów uszypułowanych. Przedstawiono technikę, zalety i wady licznych metod i ich m...

Późne wyniki wcześnie rozpoczętego leczenia rozwojowej dysplazji stawu biodrowego aparatem odwodzącym

Wstęp. Rozpoczynanie leczenia rozwojowej dysplazji stawu biodrowego w pierwszych tygodniach życia dziecka przynosi dobre wyniki. Mało jest doniesień o tym czy u tych dzieci dochodzi do pełnej anatomicznej odbudowy stawu....

Download PDF file
  • EP ID EP429881
  • DOI 10.5604/01.3001.0012.8276
  • Views 95
  • Downloads 0

How To Cite

Marcin K. Waśko, Marta Burbul, Krzysztof Gawroński, Artur Pepłoński (2018). D-dimer Levels are not a Good Marker for Venous Thromboembolism in Patients Before and After Total Hip Replacement. Ortopedia Traumatologia Rehabilitacja, 20(5), 401-408. https://europub.co.uk./articles/-A-429881