Decentralized Split Evaporative Condensation Refrigeration System for Metro Stations

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 2

Abstract

[Objective] Evaporative condensation refrigeration systems are characterized by energy efficiency, water conservation, space savings, not requiring ground cooling tower installations. The application of evaporative condensation refrigeration system in metro projects is increasing in recent years. Therefore, there is a need to analyze and study the split evaporative condensation refrigeration systems for metro stations. [Method] The above system and its refrigeration principles are introduced. Taking a metro station in Beijing as example and considering its actual conditions, the applicability, type selection and configuration, equipment layout, and system energy efficiency of the evaporative condensation refrigeration system are analyzed. Common issues in engineering application of evaporative condensation systems such as fire condition, piping length, water quality treatment, waterproofing and corrosion prevention are addressed. [Result & Conclusion] Compared to conventional chilled water screw unit refrigeration systems, the split evaporative condensation refrigeration system has certain energy-saving advantages. During fire conditions, it is essential to ensure that the combustion performance of the embedded evaporative condensation device in the wind wall reaches Class A non-combustibility level. Effective fire sealing measures should be implemented at the installation location. Adopting effective water treatment measures will reduce the impact of limescale condensation on the efficiency of the evaporative condensation refrigeration system. Piping lengths between units should be controlled within a reasonable range to minimize the impact on the refrigeration capacity and energy efficiency ratio of the system. Waterproofing treatment is recommended for the windward side walls and the ground around the evaporative condensation device.

Authors and Affiliations

Qi WANG, Yi ZHENG

Keywords

Related Articles

Platform Width Calculation Methods for Metro Large Passenger Flow Station Based on Passenger Behavior

Objective According to GB 50157—2013 ′Code for design of metro′, the calculated platform width of metro large passenger flow station is often too narrow to afford the immense passenger flow pressure effectively. Consider...

Comparative Study on Carbon Footprint Accounting of Side Wallboard for Rail Vehicles

Objective By studying the carbon footprint of two kinds of side wallboard made of different materials for rail vehicles, the accounting method for the carbon footprint of interior products is explored to guide designers...

Train Bearing Fault Diagnosis Based on Convolution Temporal-spatial Mutual Fusion Network

Objective The diverse and complex operating environment of axle box bearings makes it challenging for bearing fault diagnostic methods to achieve satisfactory results with the single sensor. To address this issue, resear...

Research on Site Selection of Emergency Rescue Station in Urban Rail Transit Line Network Based on P-center Model

Objective With the expansion of urban rail transit line network, the system risks become more complicated and uncontrollable. In order to improve the emergency rescue capability of urban rail transit system, site selecti...

Simulation Research on Train Derailment and Collision Accident in Urban Rail Transit

Objective The process of a stainless steel train body derailment accident in urban rail transit in 2015 is simulated, reproducing the direct cause and process of the car body damage in the complex accident scene. Method...

Download PDF file
  • EP ID EP730106
  • DOI 10.16037/j.1007-869x.2024.02.041
  • Views 35
  • Downloads 0

How To Cite

Qi WANG, Yi ZHENG (2024). Decentralized Split Evaporative Condensation Refrigeration System for Metro Stations. Urban Mass Transit, 27(2), -. https://europub.co.uk./articles/-A-730106