Design and Implementation of Half-Bridge LLC Resonant Converter by FHA Technique

Journal Title: روش های هوشمند در صنعت برق - Year 2015, Vol 6, Issue 21

Abstract

Although in existence for many years, only recently has the LLC resonant converters, in particular in its half-bridge implementation, gained in the popularity it certainly deserve. The advantages such as high efficiency, low level of EMI emissions, and its ability to achieve high power density are such features that suited for power supply demand of many modern applications such as ATX PCs and flat panel TVs. One of the major difficulties in concern with designing such converter is complex model and non-linear equations that cannot be easily used into a design procedure. So in this paper, design is based on the assumption that input-to-output power transfer is essentially due to the fundamental Fourier series components of currents and voltages. This technique known as First Harmonic Approximation (FHA) and is a proper method to obtain the voltage gain through solving the equivalent ac circuit of the resonant tank. The design simulated by Pspice and finally the experimental results show design procedure base on FHA technique.

Authors and Affiliations

Navid Salehi, Majid Dehghani

Keywords

Related Articles

A Novel Approach for Earthing System Design Using Finite Element Method

Protection of equipment, safety of persons and continuity of power supply are the main objectives of the grounding system. For its accurate design, it is essential to determine the potential distribution on the earth sur...

Design and Simulation of a High Step-up Three Level Boost Converter with Coupled-Inductor and Passive Clamp

Recent developments in renewable energy sources has created demands for high step-up and high efficiency DC-DC converters. This demands are fulfilled basically through the use of high frequency transformer to achieve the...

Analysis of Bifurcation Phenomenon in a Grid-Connected Electric Arc Furnace

This paper aims to study the stability and dynamic behavior of a grid-connected electric arc furnace system, using bifurcation theory. This theory introduces a systematic method for stability analysis of dynamic systems,...

Classification and Feature Extraction of Electroencephalogram Signals for Epilepsy Using PCA, ICA, DWT and SVM Methods

The purpose of this article is to classify electroencephalogram signals into two types of epilepsy and healthy. To achieve the highest accuracy, various techniques have been used. The desired characteristics of these sig...

Reliability Evaluation of Power System SVC Types Using a Markov Chain

Static reactive power compensator (SVC) plays an important role in power system reliability stems. In evaluations of reliability, only reactive power is considered as a constraint network is placed in the SVC Brrsy‌Ha im...

Download PDF file
  • EP ID EP327673
  • DOI -
  • Views 122
  • Downloads 0

How To Cite

Navid Salehi, Majid Dehghani (2015). Design and Implementation of Half-Bridge LLC Resonant Converter by FHA Technique. روش های هوشمند در صنعت برق, 6(21), 53-60. https://europub.co.uk./articles/-A-327673