Design and Simulation of Novel Gated Integrator for the Heavy ion Beam Monitors System

Journal Title: American Journal of Engineering and Applied Sciences - Year 2017, Vol 10, Issue 1

Abstract

Abstract In this study, the objective is to realize a Gated Integrator (GI) circuit for silicon strip, Si(Li), CdZnTe and CsI detectors etc. With the development of radioactive ion beam physics, heavy-charged particles like carbon ions have been applied to the treatment of deep-seated inoperable tumors in the therapy terminal of the Heavy ion Research Facility in Lanzhou (HIRFL) located at the Institute of Modern Physics (IMP), Chinese Academy of Sciences (CAS). A high resolution current measurement circuit was developed to monitor the beam current at 1pA range. The circuit consisted of a low current high sensitivity I/V converter and gated integrator in an energy spectroscopy. A low offset voltage precision amplifier and new guarding and shielding techniques were used in the I/V converter circuit which allowed to measure low current. This paper will show a MOS switch configuration which is used to prevent leakage current and novel technique to compensate a charge injection in the reset switch. Copyright © 2017 Djamet Yimga Arnaud, Wembe Tafo Evariste and Essimbi Zobo Bernard. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Authors and Affiliations

Djamet Yimga Arnaud, Wembe Tafo Evariste, Essimbi Zobo Bernard

Keywords

Related Articles

Robustness of XFEM Method for the Simulation of Cracks Propagation in Fracture Mechanics Problems

Abstract In the present paper a numerical sensitivity analysis is presented with the aim to assess the effectiveness of the X-FEM method for fracture mechanics applications. Different test cases have been adopted for th...

Key-Hole Notches in Isostatic Graphite: A Review of Some Recent Data

Abstract Fracture of the breakable isostatic graphite is concerned using the experimental and theoretically, the plates containing nicks holes key subject to varying degrees of mixed task. The main purpose of this work...

Technique for In-Vivo Measurements of Heart Deformation Using Digital Image Correlation

Affagard, S.J., P. Feissel and S.F. Bensamoun, 2015. Measurement of the quadriceps muscle displacement and strain fields with ultrasound and Digital Image Correlation (DIC) techniques. IRBM, 36: 170-177. DOI: 10.1016/j.i...

An Overview of Energy Loss Reduction (ELR) Software Used in Pakistan by WAPDA for Calculating Transformer Overloading, Line Losses and Energy Losses

Abstract This paper is about the use of ELR software for different analysis on distribution system up-gradation. It can be used in low budget countries in which distribution system is already overload and it is too much...

Flexible Stem Trabecular Prostheses

Abstract The complex biomechanics and morphology of the femur proximal epiphysis are presented. This specific region in human femur is characterized by a high flexibility compared to that of other primates, since evolve...

Download PDF file
  • EP ID EP201244
  • DOI 10.3844/ajeassp.2017.134.141
  • Views 81
  • Downloads 0

How To Cite

Djamet Yimga Arnaud, Wembe Tafo Evariste, Essimbi Zobo Bernard (2017). Design and Simulation of Novel Gated Integrator for the Heavy ion Beam Monitors System. American Journal of Engineering and Applied Sciences, 10(1), 134-141. https://europub.co.uk./articles/-A-201244