Design of the Pulse Oximetry Measurement Circuit and Its Sensing System Based On CMOS

Abstract

The pulse oximetry circuit and its sensing system is designed based on the standard CMOS technology of 0.18um. The reflection oxygen sensor is used to collect the pulse oximeter signal of human body, then the collected physiological signals are processed by the data processing circuit The data processing circuit is composed of two parts: the amplifying circuit and the band-pass filter circuit, and the pulse oximeter data processed by the data processing circuit is written into the tag through the SPI communication The RFID reader read the data in the RFID tag through wireless communication, and display the data . The experimental results show that the maximum error is ±1%. The maximum error of the pulse is ±1.9%. The stability and feasibility of pulse blood oxygen sensing system is demonstrated in this paper and it will have a good application prospect in the direction of wearable medical wisdom research.

Authors and Affiliations

Yang Wang, Liying Chen

Keywords

Related Articles

Implementation of Space Vector Pulse Width Modulation Technique on Three Phase Two Level Inverter

This paper discusses the theory and operation of Space Vector Pulse Width Modulation (SVPWM) and explains the implementation of SVPWM for the two level inverter topology.Variable voltages and frequency supply to ac drive...

Magneto Optic Current Transformer Technology (MOCT)

An accurate electric current transducer is a key component of any power system instrumentation. To measure currents power stations and substations conventionally employ inductive type current transformers .For high volta...

Sustainable Biodiesel Reactor Prototype Energetically Powered By Solar Energy

The study of routes aiming the implementation and use alternative energy sources has increased exponentially during the last decades, due to reduction of petroleum reserves and environmental damage related to fossil fuel...

Malaria parasitaemia and socioeconomic status of selected residents of Emohua community, Rivers State, Nigeria

In Nigeria, malaria consistently ranks among the five most common cause of death in children. This study investigated the prevalence of malaria and socioeconomic status of someresidents of Emohua Community, Rivers State,...

Multimodal biometric system based on Matching Score Level Fusion of Palm print And Finger print.

In multimodal biometric technique strength of unimodal system biometrics are combined to increase recognition accuracy of the system. In this paper palm print and finger print biometrics are used to design robust recogni...

Download PDF file
  • EP ID EP389102
  • DOI 10.9790/1676-1201046470.
  • Views 157
  • Downloads 0

How To Cite

Yang Wang, Liying Chen (2017). Design of the Pulse Oximetry Measurement Circuit and Its Sensing System Based On CMOS. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(1), 64-70. https://europub.co.uk./articles/-A-389102