Abstract

Objective To establish the internal quality control standard of leukocyte-depleted suspended red blood cell volume in our center, so as to guide the preparation of components, strengthen the internal quality control and improve the quality of blood preparations. Methods A total of 1 523 bags of whole blood collected using two manufacturers′ leukocyte-depleted blood bags from March to August 2023 at our center were extracted. The blood before and after filtration were weighed, and the volume of whole blood collected, the volume of filtration loss and the product volume based on the formula and measured specific gravity were calculated. According to the data distribution characteristics, the reference range of leukocyte-depleted suspended red blood cell volume was determined, and the differences of whole blood collection volume, filtration loss capacity and product capacity between the two manufacturers were analyzed. The quality control data of leukocyte-depleted red blood cells over the past year with the difference between another 100 bags of these cells and the reference interval were compared, and the effectiveness of reference interval was validated. Results The median whole blood collection volume in the sample size was 402.0 mL, with a median filtration loss of 42.4 mL, and an average volume of leukocyte-depleted suspended red blood cells at 322.5 mL. The whole blood collection volume (A: median 404.4 mL; B: median 397.7 mL, P<0.01) and the volume of leukocyte-depleted suspended red blood cell products (A: mean 331.4 mL; B: mean 312.0 mL, P<0.01) using manufacturer A′s leukocyte-depleted blood bag were both higher, with a lower filtration loss capacity (A: median 39.5 mL; B: median 46.6 mL, P<0.01). The standard deviation of the volume of leukocyte-depleted suspended red blood cell was 19.6, and the reference interval was 284.1-360.9 mL. The validation samples and quality control sampling data showed no difference from the interval samples (P>0.05). Conclusion According to the actual situation of our center, the volume standard of leukocyte-depleted suspended red blood cells in our center is determined to be 284.1-360.9 mL.

Authors and Affiliations

Xin CAO, Nana PING, Jin DING, Peng PENG, Na LIU, Yutong ZHANG, Na FENG

Keywords

Related Articles

Passenger lymphocyte syndrome after liver transplantation in a blood group AB recipient with a blood group A donor: a case report

Objective To explore the laboratory monitoring procedure and its clinical significance in patients with passenger lymphocyte syndrome after liver transplantation. Methods The Hb and bilirubin levels were monitored in one...

Identification of B(A) subtype and analysis of bood transfusion strategiaes

Objective To investigate the serology and genotype identification method of B (A) subtype patients. Methods Test tube method (serology) was used to confirm the clinically difficult ABO blood group samples of 3 patients w...

Research on characteristics of potential blood donors and influencing factors of blood donation intention

Objective To investigate the demographic characteristics and factors affecting the willingness to donate blood among potential donors in China, so as to improve the recruitment efficiency for blood donors. Methods Non-bl...

Analysis on the willingness of whole blood donors to donate apheresis platelets and its influencing factors

Objective To investigate the willingness of whole blood donors to donate apheresis platelets and analyze its influencing factors. Methods A total of 400 whole blood donors from Kunshan Blood Station and Leshan Blood Stat...

Exploration of the relationship between the storage time of leukodepleted red blood cell and transfusion adverse reactions

Objective To explore the relationship between the storage time of leukodepleted red blood cells and transfusion adverse reactions by analyzing the occurrence of transfusion adverse reactions of patients after leukodeplet...

Download PDF file
  • EP ID EP748052
  • DOI 10.13303/j.cjbt.issn.1004­549x.2024.09.013
  • Views 39
  • Downloads 0

How To Cite

Xin CAO, Nana PING, Jin DING, Peng PENG, Na LIU, Yutong ZHANG, Na FENG (2024). Determination and analysis of reference interval of leukocyte-depleted suspended red blood cell volume in Xi′an. Chinese Journal of Blood Transfusion, 37(9), -. https://europub.co.uk./articles/-A-748052