Device for Detecting Glaucoma

Journal Title: Biomedical Journal of Scientific & Technical Research (BJSTR) - Year 2019, Vol 14, Issue 1

Abstract

This is a diagnostic device to measure the Intraocular Pressure (IOP) of eyeball, a key indicator for glaucoma. This is a degenerative disease characterized by progressive loss of visual field. According to Glaucoma society of India 12 million people are affected by Glaucoma i.e. 12.8 % of total cases of blindness. About half of glaucoma patients go undetected until they lose substantial vision and suffer from irreversible loss of visual function if untreated. The innovative device being developed is expected to help in early detection, screening, and treatment of glaucoma, the leading preventable cause of blindness. The degenerative disease glaucoma is the world’s leading cause of preventable blindness. Glaucoma stems from optic nerve damage due to a buildup of Intraocular Pressure (IOP) in the eyeball. Normal IOP ranges between 10-21mm Hg. After 23mm Hg, the risk of glaucoma increases by 10% for every additional 1mm Hg pressure. Higher pressure damages the neuronal tissue in the optic nerve head (lamina cribrosa). Current treatment involves reducing the pressure to slow the progression of the disease. This requires accurate methods to measure IOP [1]. The intraocular pressure is a fundamental parameter of ocular health and disease, with major importance in the diagnosis and management of glaucomatous conditions. The most common cause of chronically elevated IOP is a decrease of trabecular outflow. If this state persists, glaucomatous condition may be developed (Figure 1). Unfortunately, nearly 50% of people with glaucoma may go undetected until they have lost substantial vision. Glaucoma stems from optic nerve damage due to a buildup of Intraocular Pressure (IOP) in the eyeball. Normal IOP ranges between 10- 21mm Hg. After 23mm Hg, the risk of glaucoma increases by 10% for every additional 1mm Hg pressure. Higher pressure damages the neuronal tissue in the optic nerve head (lamina cribrosa), (Figure 2). Current treatment involves reducing the pressure to slow the progression of the disease. This requires accurate methods to measure IOP. The innovative device being developed is expected to help in early detection, screening, and treatment of glaucoma, the leading preventable cause of blindness [2].

Authors and Affiliations

Mahesh B Mawale, Ravi shekhar Dhakate, Shantidas Lunge

Keywords

Related Articles

Group A Streptococcal Pharyngotonsillitis

Group A streptococcus is the most frequently identified bacterium in children with acute pharyngotonsillitis [APT], although group B, C, F, and G have also been associated with APT. In Leao SC study higher APT incidence...

A New Perspective of Agroecosystem in 21st Century

Land is a living legend, including all eroded and forest land that all would contribute to agriculture. In a wider perspective, a long-term view will have to be taken to manage our soil, plant and bio-resources. Sustaina...

Ameliorative Role of Composite Flour Against Human Maladies

Cereals are used by humans since long from prehistoric times and are rich sources of macro and micronutrients. They are considered as staple food and provide significant amount of proteins, carbohydrates, vitamin B and m...

Class Based Variable Importance for Medical Decision Making

In this paper we explore variable importance within tree-based modeling, discussing its strengths and weaknesses with regard to medical inference and action ability. While variable importance is useful in understanding h...

Potential Parameters in Assessment of Testicular Toxicity

Testicular toxicity accounts for about 50 % of infertility cases in men. Though, there are several approaches to detect the testicular toxicity, the histopathological study of alterations occurred in the seminiferous tub...

Download PDF file
  • EP ID EP585625
  • DOI 10.26717/BJSTR.2019.14.002482
  • Views 140
  • Downloads 0

How To Cite

Mahesh B Mawale, Ravi shekhar Dhakate, Shantidas Lunge (2019). Device for Detecting Glaucoma. Biomedical Journal of Scientific & Technical Research (BJSTR), 14(1), 10338-10341. https://europub.co.uk./articles/-A-585625