Diagnostic performance of automated Analyzers versus manual method for WBCs measurement among Population of Wad Madani, Gezira State, Sudan

Journal Title: Scholars Journal of Applied Medical Sciences - Year 2017, Vol 5, Issue 3

Abstract

Abstract: The automated hematology analyzer with complete blood count (CBC) results has replaced the traditional manual or individual assay methods for hematological parameters and the eye count leukocyte differential as the initial screening and detection system for hematological abnormalities in modern hospitals and clinics. Automated method for the estimation of complete blood count is commonly used in routine practice laboratory but many other labs still work on manual procedure for the abnormal automated results as well as health care workers in laboratory can be optimized by doing test on manual microscopic procedure as validation technique for automated method. This study carried out to compare the WBCs by different automated analyzers and manual method. Study carried out in Wad Madani city capital of Gezira State, central Sudan during the period of July to August 2016. The study included 75 healthy individuals selected randomly, 31 of them were males and 44 were females, their age ranges from 20 to 50 years who came for medical examination. Three mls of venous blood were collected from participants in EDTA anticoagulant. The samples were analyzed using haemocytometer, Sysmex XP-300 and Mindray BC-6800.The results showed that repeatability of white blood cells by chamber, mindray and sysmex were (5.1707, 5.0293, 4.9560), (5.8680, 5.8573, 5.8507) and (6.0093, 5.9800, 5.9627) ×10³µl respectively, there was no significant different between the repeated result for manual and mindray but there was significant different by sysmexP.value (0.04). And when we compared the means+ SD of white blood cells by manual, mindray and sysmex were (5.0520±1.6460), (5.8587±1.7355) and (5.9840±1.7130)× 10³µl respectively, there was highly significant different by all three method P.value (0.001).Our study concluded that, there was no significant difference between repeatability of WBCs by manual and Mindray, significant difference between repeatability of WBCs by Sysmex and application of automated method is easier when there is load of work which takes less time. Keywords:White blood cells, automated hematology Analyzers,Manual Method

Authors and Affiliations

Tayseer Ibrahim Elsidigge, AlbadawiAbdelbagi Talha, Mohammed Siddig Younis

Keywords

Related Articles

A Preliminary Evaluation of Stool Antigen Test in H. pylori Infections

Abstract: The discovery of Helicobacter pylorirevolutionised the concept of gastroduodenal pathology& diverted the world wide attention from pH to Hp (H. pylori). Surgical management is replaced by antibiotics. Endoscopy...

Aspiration and Methyl Prednisolone Injection into the Cyst in the Treatment of Wrist Ganglia: Experience at a Rural Medical College

The objective of the study was to evaluate the results of aspiration combined with injection of methyl prednisolone in the treatment of wrist ganglions. It was a prospective study from March 2010 to April 2013 that compr...

Review of Difficult Airway Management

Abstract: The incidence of difficult airway and it's management frequently occur in the operating room. The anesthesiologists possess important responsibility to manage the difficult airway. Airway difficulties may be an...

Study on Blood Supply of Appendix and Caecum in Human Cadavers and Its Variations

The size, shape, position and arterial supply of the caecum and appendix vary in different individuals of different sex and age. Therefore, a thorough knowledge of normal and abnormal anatomy, arterial supply of the caec...

Apolipoproteins and Serum Lipid Profile in Acute Myocardial Infarction

Acute Myocardial Infarction [AMI] is now a common disease with serious consequences in mortality and morbidity. Altered lipid profile with low HDL-C and high LDL-C and TGs has been implicated in coronary atherosclerosis....

Download PDF file
  • EP ID EP371465
  • DOI -
  • Views 89
  • Downloads 0

How To Cite

Tayseer Ibrahim Elsidigge, AlbadawiAbdelbagi Talha, Mohammed Siddig Younis (2017). Diagnostic performance of automated Analyzers versus manual method for WBCs measurement among Population of Wad Madani, Gezira State, Sudan. Scholars Journal of Applied Medical Sciences, 5(3), 1014-1018. https://europub.co.uk./articles/-A-371465