Diagnostic Value of Digital Radiography in Gap Detection of Implant-Abutment Connection with Zirconia Abutments in Different Vertical X-ray Projection Angles

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 5

Abstract

ABSTRACT Introduction: Accurate seating of abutments on implants is an important factor for long term success of implant supported restorations. Among different methods of evaluating abutment seating, radiography is most commonly used, while some clinical factors such as angulation of radiography film and radiography tube can adversely affect its diagnostic value. Aim: To evaluate diagnostic value of digital periapical radiographs in terms of sensitivity, specificity and accuracy of gap detection at implant-abutment connection with different angles of X-ray projection when using a zirconia abutment. Materials and Methods: In this in vitro study radiographs were made of three different implant connections (internal tri-channel, external hex and internal hex with platform switching) to which zirconia abutments were fastened, once with and once without using a spacer between implant and abutment. Radiographs were taken at different projection angles of -20, -15, -10, -5, 0, +5, +10, +15, and +20. Then 10 prosthodontists were asked to assess all the radiographs, two times for each one with an interval of 10 days. Sensitivity, specificity and accuracy indices were calculated for each system. Results: Findings showed that sensitivity of gap detection in all study groups was amongst acceptable range (85-100%). In general external hex connection system showed better results (95-100%) while the platform switching internal hex system had the weakest results (85-100%). Conclusion: Angle of X-ray projection is better to be between -10 to +10 when evaluating complete seat of zirconia abutments on implants especially if a platform switching system is used.

Authors and Affiliations

Marzieh Alikhasi, Alireza Salehi, Maryam Memarian, Mahtab Tabesh

Keywords

Related Articles

Autism Spectrum DisordersAetiopathogenesis

Autism Spectrum Disorders (ASD) are characterised by a range of clinical features that can vary from individual to individual in both degree of severity and variability of the clinical presentation. The aetiology or caus...

Recall of Complications and Satisfaction of Consent in Mandibular Third Molar Surgery: A Randomised Controlled Single Blind Study

ABSTRACT Introduction: Informed consent prior to any medical procedure is important for legal, ethical and administrative reasons. Informed consent intends to improve the patients’ knowledge which will allow involvement...

Influence of Storage Time and Cementation Strategies on Push-Out Bond Strength of Fiber Posts to Root Dentin

Introduction: The restoration of structurally compromised endodontically treated teeth pose most challenging adhesive restorative procedure and controversies still exist about which material or technique are best for the...

Successful Management of the Masochistic Habit in a Child with Santovuori-HaltiaHagberg Disease (Infantile Neuronal Ceriod Lipofuscinoses)

Self-injurious behaviours are usually related to paediatric patients with mental retardation. The management of such patients is quiet challenging to the paediatric dentists because of the difficulty to communicate with...

Download PDF file
  • EP ID EP524445
  • DOI 10.7860/JCDR/2018/34540.11509
  • Views 83
  • Downloads 0

How To Cite

Marzieh Alikhasi, Alireza Salehi, Maryam Memarian, Mahtab Tabesh (2018). Diagnostic Value of Digital Radiography in Gap Detection of Implant-Abutment Connection with Zirconia Abutments in Different Vertical X-ray Projection Angles. Journal of Clinical and Diagnostic Research, 12(5), 15-18. https://europub.co.uk./articles/-A-524445