Disturbance Deformation Influence and Field Measurement Study of Metro Shield Under-passing High Building Foundation

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 4

Abstract

Objective With an increasing number of cases involving metro shield tunneling through or in proximity to high buildings in urban rail transit projects, the shield tunneling method inevitably causes disturbances to the ground due to its unique construction process. In several cases, it may impact the structural safety of existing buildings. Therefore, an in-depth study of the force characteristics on both the tunnel and high buildings during shield tunneling is necessary. Method Leveraging the tunnel construction project of Shengchan Road Sta.-Lihuang Road Sta. interval on Jinan Metro Line R2, a 3D finite element numerical method is employed to simulate the construction process of double-line shield tunnels asynchronous oblique angle under-passing a group of high buildings with pile and raft foundations. Combining with field-monitored data, the law of ground displacement, deformation characteristics of building settlements, and the control effectiveness of shield tunneling parameters during construction are analyzed. Result & Conclusion When the double-line shield tunnels successively pass beneath the building pile group, the land subsidence caused by leading tunnel excavation is relatively significant, while the disturbance to the ground from subsequent tunnel excavation is relatively small. The maximum subsidence occurs when the shield tunnel is directly beneath the building, and as the shield tunnel moves away, the subsidence gradually decreases and tends to stabilize. Due to the framed structure of the high buildings, partial subsidence occurres on the building area adjacent to the tunnel side, while the part far away from tunnel exhibits an upheaving trend. However, the differences in subsidence amount between the two scenarios remain within a manageable range.

Authors and Affiliations

Kun ZHANG, Qianwei XU, Qingwen SUN, Hairu XUE, Shouxi LAI

Keywords

Related Articles

Impact Analysis of New Shield Tunnel Under-passing Construction on Existing Railways

[Objective] The construction of new shield tunnels under-passing existing railway can cause deformation of the former railway subgrade. To ensure the stability and safety of the existing railway, appropriate reinforcem...

Simulation and Evaluation Model of Operation Delay Adjustment Plan for Urban Rail Transit Express and Local Trains

Objective Making a reasonable train delay adjustment plan is one of the key tasks to ensure the safe and reliable operation of urban rail transit lines. For those lines with express and local trains running on, it is nec...

Empirical Research on Urban Rail Transit and Urban Economic Low-carbon Transformation

[Objective] Urban rail transit system is an important part of modern urban economy. To better realize the low-carbon transformation of urban economy, attention should be given to the impact of urban rail transit system o...

Discussion on Integrated Supervisory Control System 2.0 for Urban Rail Transit

[Objective] In order to solve the deficiencies of the traditional integrated supervision and control system (ISCS) of urban rail transit, such as outdated system architecture, insufficient system integration and complex...

Sparse Total Focus Imaging of Rail Transit Rail Defects Based on Grey Wolf Algorithm

[Objective] Using the ultrasonic phased array technology can realize high-precision imaging detection of rail transit rail defects. However, the widely used FMC-TFM (full matrix capture-total focusing method) has the dis...