Dose Calibration and Track Diameter Distribution for 241Am-Be Neutron Source, Using CR-39 Nuclear Track Methodology

Abstract

In neutron detection, the more common method is using electronic instrumentation associate with Bonner spheres, however, currently the Nuclear Tracks Methodology (NTM) is coming popular because of the simplicity, flexibility in size of the detector, no requirement for sophisticated instrumentation and installation, and low cost. In this work, a preliminary result of the dose calibration and track diameter distribution of Americium-Beryllium (241Am-Be) source using Nuclear Track Methodology is presented. As material detector, CR-39 polycarbonate, cut in 1.8 × 0.9 cm2 chips was chosen, and two step chemical etchings after neutron exposure was used to develop the tracks. The irradiations were made in environmental normal conditions, in the ORNL neutron calibration facilities. The CR-39 chips were placed in a phantom, with 3mm plastic (Lexan) sheet in between the source and detectors to increase the proton generation. The total track density and track diameter distribution was performing in a Counting and Analysis Digital Image System (CADIS), developed at the Institute of Physics of the University of Mexico UNAM. The results are compared with a standard survey instrument and energy reference spectra of the International Atomic Energy Agency (IAEA).

Authors and Affiliations

J. S. Bogard , J. I. Golzarri , G. Espinosa

Keywords

Related Articles

On the Fusion of Neutron/ Proton-Rich Colliding Nuclei Using Isospin-Dependent Potentials

By using different isospin dependent proximity-type potentials, we performed a detailed study of neutron/proton-rich colliding nuclei with N/Z ratio between 0.5 and 2.0. Isotopes of three different series namely, Ne-Ne,...

Radon in Workplaces the Urgent Need of New Measurements and Devices.

The existing passive radon monitors, their relative calibration facilities together with the past intercomparison exercises have been mission-oriented towards radon measurements in dwellings. These monitors have been suc...

Application of a CdTe Detector for Measurements of Mammographic X-ray Spectra

This work aims to characterize mammographic x-ray beams incident and transmitted by breast phantoms (from 0 to 45 mm) composed from known proportion of glandular and adipose tissue-equivalent materials. This study was pe...

Proposal of a Novel Setup for Linac Monitoring Using a Specifically Designed Plastic Scintillator and a Spectrophotometer

In this work, we report the design, implementation, and results of an alternative monitoring system for a linear accelerator (LINAC) used in medical therapy. The system proposed consist in as lab of scintillator plastic...

Atomic Multiplet and Charge Transfer Effects in the Resonant Inelastic X-Ray Scattering (RIXS) Spectra at the Nickel L2,3 Edge of NiF2

Resonant inelastic x-ray scattering (RIXS) is used to study the electronic structure of NiF2, which is the most ionic of the nickel compounds. RIXS can be viewed as a coherent two-steps process involving the absorption a...

Download PDF file
  • EP ID EP596763
  • DOI 10.15415/jnp.2018.61013
  • Views 243
  • Downloads 0

How To Cite

J. S. Bogard, J. I. Golzarri, G. Espinosa (2018). Dose Calibration and Track Diameter Distribution for 241Am-Be Neutron Source, Using CR-39 Nuclear Track Methodology. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(1), 77-80. https://europub.co.uk./articles/-A-596763