Dosimetry Comparison of CBCT versus Digital 2D Orthodontic Imaging in a Pediatric Orthodontic Patient

Journal Title: Journal of Dental Health and Oral Research - Year 2021, Vol 2, Issue 2

Abstract

The purpose of the study was to evaluate the amount of radiation potentially absorbed by a pediatric patient during whole-head (13x15 cm) CBCT imaging compared with digital panoramic and lateral cephalometric imaging using the same machine. For each of the three imaging modalities, twenty-one nanoDot Optically Stimulated Luminescent Dosimeters (OSLDs) were placed in a pediatric anthropomorphic 10-year old phantom in order to record absorbed radiation doses at different radiosensitive locations. All imaging was performed using the manufacturer’s recommended exposure settings. Ten more runs were performed with an OSLD placed only at the thyroid. A Monte Carlo Analysis was performed to extrapolate the absorbed doses for the remaining twenty organ locations. Equivalent doses for the head and neck organs and overall effective doses was determined using the International Commission on Radiological Protection’s tissue weighting factor guidelines. For each of the organs tested, there was a statistically significant differences in radiation doses across the three imaging modalities. The highest radiation doses were observed in CBCT imaging for all organs. The average effective dose was higher in CBCT than in lateral ceph and panoramic imaging combined. The results of the study suggest that in order to reduce pediatric patient radiation exposure during routine orthodontic records, conventional 2D imaging with digital panoramic and lateral cephalometric modalities should be used preferentially over CBCT imaging.

Authors and Affiliations

AB Albin, AD Goren*, RD Faber, NK Anderson, LT Dauer, B Quinn, D Miodownik, K Kelly, I Branets, DC Colosi, M Mahdian

Keywords

Related Articles

Malpractice Payments and Adverse Actions against Dentists in Texas-A Fifteen-Year Trend Analysis

Objective: Health practitioners are potentially subject to malpractice claims against them and previous research has indicated that legal proceedings against dentists are becoming a larger proportion of all malpractice p...

Regenerative Endodontics -Present Practice to Promising Prospects: A Literature Review

Regenerative endodontics is an innovative field within dentistry that aims to restore damaged dental pulp using stem cells, tissue engineering techniques and biocompatible materials. This article provides an overview of...

Editorial Board Representation by Women in Leading Dental Journals

Background: Gender imbalances persist in high-ranking leadership roles, particularly in academia. Extensive research has revealed a consistent lack of representation of individuals with a female gender expression as jour...

Cultivating Healthy Smiles: Exploring Regenerative Therapy in Periodontics

Regenerative therapy is a cutting-edge therapeutic strategy used in periodontics with the goal of restoring the health and functionality of the tissues that support teeth, including the periodontal ligament, bone and gum...

Dentistry at the Crossroad-Profession and Entrepreneurship

Profession is a paid occupation involving prolonged and specialized preparation and training at the level of higher education. Dentist is a profession that focused on serving the oral health needs of patients and socie...

Download PDF file
  • EP ID EP699015
  • DOI http://dx.doi.org/10.46889/JDHOR.2021.2201
  • Views 87
  • Downloads 0

How To Cite

AB Albin, AD Goren*, RD Faber, NK Anderson, LT Dauer, B Quinn, D Miodownik, K Kelly, I Branets, DC Colosi, M Mahdian (2021). Dosimetry Comparison of CBCT versus Digital 2D Orthodontic Imaging in a Pediatric Orthodontic Patient. Journal of Dental Health and Oral Research, 2(2), -. https://europub.co.uk./articles/-A-699015