EFFECT OF CARRIER GAS FLOW RATE AND COLUMN TEMPERATURE ON THE SUITABILITY PARAMETERS OF GC-ECD FOR SF6 MEASUREMENT
Journal Title: Periódico Tchê Química - Year 2017, Vol 14, Issue 28
Abstract
System suitability testing of a GC is essential to verify its suitability for intended application. The GC always uses a carrier gas and column temperature, which may impact on its suitability parameters. This study is aimed to evaluate the effects of carrier gas flow rate (FLRT) and column temperature (CLTP) on the system suitability parameters (SSP) of GC-ECD for SF6 measurement such as retention time/tR, response factor/RF, theoretical plate numbers/N, and asymmetric factor/As. The evaluation was conducted by carefully profiling the SF6 chromatogram and the data obtained were used to calculate the tR, RF, N, and As values. It was found that the tR increases linearly (R2 = 0.9978) by increasing the FLRT, but decreases linearly (R2 = 0.9991) by increasing the CLTP. The RF decreases linearly (R2=0.9939) by increasing the FLRT. Interestingly, the RF was affected by the CLTP with 2nd polynomial order trend (R2=0.9949). The N increases linearly (R2 = 0.9404) by increasing the FLRT but the N was affected by the CLTP with 2nd polynomial order trend (R2 = 0.9769). The As was found to increase slightly with FLRT (R2 = 0.1288), while the As was affected by the CT with 2nd polynomial order trend (R2 = 0.9778). These results are in a good agreement with previous SSP studies.
ANALYSIS AND SYNTHESIS OF LITERATURE ON THE ASPECTS OF STRIP ELECTRODE FUSION DURING OVERLAY WELDING OF THE SEALING SURFACES OF PIPELINE ACCESSORIES
The paper considers questions about the features of strip electrode overlay welding of the sealing surfaces of industrial pipeline fittings for nuclear power plants (NPPs). The analysis of literature data, scientific pub...
BACTERIOLOGICAL QUALITY EVALUATION AND WATERS CHLORINATION OF THE COLLECTIVE ALTERNATIVE SOLUTIONS (CAS) IN COMPLIANCE WITH HEALTH MINISTRY ORDONNANCE N ° 2914 OF DECEMBER 12, 2011
CAS correspond to the modalities of supply different from the public systems and have been monitored by the Program of Surveillance of the Water Quality for Human Consumption, aiming at the health protection. The free ch...
ANALYSIS OF ALDICARB IN SURFACE WATER FROM THE PARANÁIBA RIVER
The pesticide aldicarb is the most toxic active ingredient registered in all national territory, standing out for its extreme acute toxicity. In the environment, mainly in the water resources, several studies have demons...
DEVELOPMENT OF SULFENTRAZONE EXTRACTION PROCEDURE FROM COMMERCIAL HERBICIDE FORMULATION AND DETERMINATION OF ITS IONIZATION CONSTANT (pKa) BY POTENTIOMETRIC TITRATION
The herbicide sulfentrazone (SFZ) is widely used in soybean and sugarcane crops, although it is classified as very dangerous to the environment. To minimize barriers to the development of research with this herbicide due...
Extraction, CHEMICAL CHARACTERIZATION and ANTIMICROBIAL POTENCY of ESSENTIAL OIL of TAHITI lemon (Citrus latifolia Tanaka)
The increase in bacterial resistance to antibiotics induce the emergence of more virulent strains, with ability to cross natural barriers of defense of the organism and of becoming pathogenic, even when present in low nu...