Effect of Denture Cleansers on Surface Roughness and Flexural Strength of Heat Cure Denture Base Resin-An In vitro Study

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 8

Abstract

Introduction: Denture cleansing is essential for maintaining the prosthesis and oral health, so choosing an appropriate cleanser which is not only efficient but also not adversely affects the properties of denture base resin itself with prolonged use is important. Hence, the present study was undertaken. Aim: To evaluate the effect of different chemical cleansers on surface roughness and flexural strength of heat cure denture base resin when used daily for three months. Materials and Methods: A total of 40 rectangular specimens (65 mm x 10 mm x 2.5 mm) and 32 disc shaped specimens (10 mm x 2 mm) were fabricated from heat cure denture base resin (DPI Heat Cure) for evaluation of flexural strength and surface roughness respectively. The specimens not subjected to cleansing served as control whereas other specimens were subjected to daily cleansing with one of the three cleansers (1% sodium hypochlorite, fittydent tablets, 100% vinegar) daily and stored in distilled water for three months. Surface analyser (Surftest SJ-210, Mitutoyo, USA) was used to evaluate change in surface roughness of the specimens (ΔRa) before and after cleansing. Also, flexural strength (S) of specimens after cleansing was evaluated by subjecting the specimens to load of 50 kgf at a crosshead speed of 5 mm/min in universal testing machine (INSTRON). Data obtained by testing was compiled and analysed using statistical software SPSS version 17.5. ANOVA and Post-hoc Tukey’s tests were used and p-value <0.05 was considered significant in all tests. Results: Results showed that the surface roughness of the specimens was significantly increased and flexural strength significantly decreased after immersion in 1% sodium hypochlorite solution for three months (p<0.05). No statistically significant difference were observed in flexural strength and surface roughness of the specimens cleaned with fittydent and 100% vinegar for three months (p>0.05). Conclusion: Within the limitations of this in vitro study, it was concluded that immersion in 1% sodium hypochlorite solutions for three months influences the surface roughness and flexural strength of heat cure denture base resin; hence it should be used with caution when used for long period. Fittydent and 100% vinegar can be recommended as a routine chemical cleansing agent for long term use.

Authors and Affiliations

Prabal Sharma, Sandeep Garg, Nidhi Mangtani Kalra

Keywords

Related Articles

Coconut Oil and Virgin Coconut Oil: An Insight into its Oral and Overall Health Benefits

Oral health is of prime importance to all individuals. The traditional use of oil in India for maintenance of good oral hygiene has been mentioned in the Vedic literature since ancient times. Oil pulling therapy also kno...

Palatogram: A Guide to Customised, Functional Palatal Contour

The prime requisite of a sound and holistic prosthodontic rehabilitation from both the patient’s and clinician’s perspective is to be able to satiate the yardsticks of function, retention, aesthetics and comfort to the f...

Merits of Oil Pulling Therapy in the Management of Xerostomia and Stomatopyrosis in Burning Mouth Syndrome

Introduction: Burning Mouth Syndrome (BMS) is a condition which is characterised by xerostomia, stomatopyrosis, dysgeusia and primarily affects the women of perimenopausal age. Despite the plethora of trials that have be...

Evaluation of Sensorineural Hearing Loss as a Consequence of Conventional Radiotherapy in Head and Neck Cancer

ABSTRACT Introduction: Sensorineural Hearing Loss (SNHL) is potentially disabling and yet overlooked, while subjecting patients of head and neck cancer to conventional ionising radiation at most tertiary care centers. Th...

A Clinical Study on Islanded Reverse Sural Artery Flap for the Reconstruction of Defects over the Lower Third of Leg and Foot

Introduction: The islanded reverse sural artery flap is a versatile, relatively simple procedure, useful in reconstruction of lower third leg, heel, tendo achilles region, malleoli and hind foot defects because of the lo...

Download PDF file
  • EP ID EP362042
  • DOI 10.7860/JCDR/2017/27307.10483
  • Views 66
  • Downloads 0

How To Cite

Prabal Sharma, Sandeep Garg, Nidhi Mangtani Kalra (2017). Effect of Denture Cleansers on Surface Roughness and Flexural Strength of Heat Cure Denture Base Resin-An In vitro Study. Journal of Clinical and Diagnostic Research, 11(8), 94-97. https://europub.co.uk./articles/-A-362042