Effect of Improper Curing on the Properties of Normal Strength Concrete

Journal Title: Engineering, Technology & Applied Science Research - Year 2018, Vol 8, Issue 6

Abstract

In real applications, 28 days are regarded as proper curing time for concrete. There is a self-evident need to minimize the duration of curing days. For this purpose, this research investigates 1 to 7 days of curing and compares it with concrete cured for 28 days. Three grades of normal concrete strength grade 30, grade 35 and grade 40 were made. After curing, two exposure conditions were applied to the concrete, inside laboratory-controlled environment and outside environment. Results indicate that slump increases with cement content in DOE method at constant water content. The concrete density in all grades reduces when the concrete is subject to inside exposure in comparison with outside exposure. Water loss from concrete reduces with increase in curing days in all concrete grades. Compression strength of all concrete grades increases with increase in curing days. For the uniformity of concrete, ultrasonic pulse velocity indicated that with an increase in curing days, concrete becomes denser and a bit void. Results showed that an increase in curing days also improves the surface quality of concrete. The significance point noticed is that there was not much difference in the concrete properties between 7 days of curing and 28 days of curing in all grades.

Authors and Affiliations

R. P. Memon, A. R. M. Sam, A. Z. Awang, U. I. Memon

Keywords

Related Articles

Reducing Torque Ripples of the Axial Flux PM Motors by Magnet Stepping and Shifting

Higher efficiency on electric machines is the research goal of many studies. An example is the axial flux permanent magnet machines. These machines have some advantages like their watt/kg efficiency and torque density. T...

Quality Improvement of a Small Water Supply. A Practical Application of a Full System of Nanofiltration

The THM level in the Spanish drinking water is limited to less than 0.100 mg/L, due to its potential toxicological effect on humans. This paper investigates the comparison of the results obtained in a small supply of wat...

Designing a GA-Based Robust Controller For Load Frequency Control (LFC)

Power systems include multiple units linked together to produce constantly moving electric power flux. Stability is very important in power systems, so controller systems should be implemented in power plants to ensure p...

Model and Reduction of Inactive Times in a Maintenance Workshop Following a Diagnostic Error

The majority of maintenance workshops in manufacturing factories are hierarchical. This arrangement permits quick response in advent of a breakdown. Reaction of the maintenance workshop is done by evaluating the characte...

Simulation and Modeling of a Five -Level (NPC) Inverter Fed by a Photovoltaic Generator and Integrated in a Hybrid Wind-PV Power System

A distributed hybrid coordinated wind photovoltaic (PV) power system was proposed in this paper. As oil and coal reserves are being depleted whilst at the same time the energy demand is growing, it is important to consid...

Download PDF file
  • EP ID EP283839
  • DOI -
  • Views 273
  • Downloads 0

How To Cite

R. P. Memon, A. R. M. Sam, A. Z. Awang, U. I. Memon (2018). Effect of Improper Curing on the Properties of Normal Strength Concrete. Engineering, Technology & Applied Science Research, 8(6), -. https://europub.co.uk./articles/-A-283839