EFFECT OF INNER ELECTRODE LENGTH OF 2.2 KJ MATHER TYPE PLASMA FOCUS ON FOCUS ACTION

Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 0, Vol 10, Issue 3

Abstract

This paper presents results of experimental studies carried out with a Mather type plasma focus device of 2.2 kJ energy. A critical effect of plasma focus inner electrode, IE length on the plasma focus action is detected for IE length has been changed to 9.5, 10.5 and 11.5 cm respectively; also for different Argon gas pressure ranging from 0.2 to 1.8 Torr. To verify this effect, it is important to investigate the plasma focus characteristics such as, a focusing time, voltage spike amplitude, focus action intensity, focus duration time, plasma focus inductance, and radius of plasma focus column as well as pinching ratio. The diagnostics used in the experiments include a Rogowski coil and resistive high voltage probe to measure the discharge current and voltage signals respectively. All the results illustrated that, the best focus action has been achieved for IE length of 10.5 cm and at filling Argon gas pressures varied from 0.8 to 1.2 Torr.

Authors and Affiliations

Hanaa Elshamy

Keywords

Related Articles

The markers to predict the response to neoadjuvant therapy in patients with rectal cancer

Locally advanced rectal cancer is currently treated with preoperative radiochemotherapy, but the response is not uniform. Most patients benefit from preoperative CRT, however, a small proportion of a patient population i...

The Linkage of the Different Distinct Great Volcanic Eruptions of the Thera (Santorini) in the Range (1700·1450 ±14) BC and the Related Subsequent Intensifications of the Global Seismicity and Volcanic Activity in the End of the 19TH Century and

The article presents the development of the cosmic geophysics (representing the deterministic the rmohydrogravi dynamic theory based on the authors generalized differential formulation of the first law of thermodynamics)...

Fine-structure constant from Sommerfeld to Feynman

The fine-structure constant, which determines the strength of the electromagnetic interaction, is briefly reviewed beginning with its introduction by Arnold Sommerfeld and also includes the interest of Wolfgang Pauli, Pa...

Some flying animals that generate aversion to humans are the bats.

The incredible faculty of perception of the bat is vinculated to their system of ubication by means of eco resonance so; they are oriented by emitting high frequency sounds orientation, and receipting the echoes. In thaw...

Enhancement of MRI Imaging by Combining Ramp Sampling and Parallel Imaging Techniques in Cerebral Tumors

Our aim was to decrease geometric distortion artifact in DWI on brain by using different MR techniques such as ramp sampling and parallel imaging. The study was done on 15 patients, They were subject to routine brain MRI...

Download PDF file
  • EP ID EP653692
  • DOI 10.24297/jap.v10i3.1319
  • Views 62
  • Downloads 0

How To Cite

Hanaa Elshamy (0). EFFECT OF INNER ELECTRODE LENGTH OF 2.2 KJ MATHER TYPE PLASMA FOCUS ON FOCUS ACTION. JOURNAL OF ADVANCES IN PHYSICS, 10(3), 2802-2810. https://europub.co.uk./articles/-A-653692