Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation – An In vitro Study

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 1

Abstract

Introduction: Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. Aim: This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. Materials and Methods: In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Results: Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). Conclusion: There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels.

Authors and Affiliations

Madhuri R Devale, MC Mahesh, Shreetha Bhandary

Keywords

Related Articles

Clinical and Laboratory Predictors of Frequency of Painful Crises among Sickle Cell Anaemia Patients in Nigeria

Introduction: The severity of Sickle Cell Anaemia (SCA) in terms of frequency of painful Vaso-Occlusive Crises (VOC) may be affected by clinical and haematological parameters amongst others. Elucidation of these factors...

Comparative Evaluation of the Efficacy of Bioactive Ceramic Composite Granules Alone and in Combination with Platelet Rich Fibrin in the Treatment of Mandibular Class II Furcation Defects: A Clinical and Radiographic Study

Introduction: Predictable closure of furcation defects with bone grafts, Guided Tissue Regeneration (GTR) and a combination of the two has remained an elusive goal so far. Hence, evaluation of biomimetic agents as candid...

Comparative Evaluation of Shear Bond Strength of Resin Modified Glass Ionomer Cement and Biodentine as Dentin Substitutes to Bonded Silver Amalgam and Composite Resin

ABSTRACT Introduction: The bond strength between the restorative material and the tooth, as well as between the restorative material and the base, is an important factor and can determine the longevity of a dental treatm...

Immunodiagnosis of Human Fascioliasis: An Update of Concepts and Performances of the Serological Assays

Human Fascioliasis (HF) is a foodborne neglected parasitic disease caused by Fasciola hepatica and Fasciola gigantica. New epidemiological data suggest that the endemic areas of the disease are expanding and HF is being...

Download PDF file
  • EP ID EP328826
  • DOI 10.7860/JCDR/2017/22059.9159
  • Views 152
  • Downloads 0

How To Cite

Madhuri R Devale, MC Mahesh, Shreetha Bhandary (2017). Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation – An In vitro Study. Journal of Clinical and Diagnostic Research, 11(1), 15-18. https://europub.co.uk./articles/-A-328826