Effect Of Location Of Lateral Force Resisting System On Seismic Behaviour Of RC Building

Journal Title: INTERNATIONAL JOURNAL OF ENGINEERING TRENDS AND TECHNOLOGY - Year 2013, Vol 4, Issue 10

Abstract

In this study the influence of location of lateral force resisting systems on the response reduction factor (R), ductility and plastic hinge status at performance point of the RC buildings were studded. The present paper made an attempt to study 4 types of 10 storey RC frame structure with different positions of shear wall on the symmetrical floor plans. Nonlinear pushover analysis has been performed using ETABS software in according with IS1893-2002. The actual values required for determination of response reduction factor (R), ductility and performance of the building are work out on the basis of pushover curve which is a plot of base shear verses roof displacement and pushover curve gives the actual capacity of the structure in the nonlinear rang. The results show that due to transfer the shear wall to the inner core, response reduction factors (R) and ductility reduce, but the number of plastic hinges beyond collapse increase. So it is essential to consider the effect of shear wall shifting for the seismic evaluation of RC buildings.

Authors and Affiliations

Mohammad Parsaei Maram , Dr. K Rama Mohana Rao

Keywords

Related Articles

 GSM Based Flexible Calling System For Coal Mining Workers

 This paper presents an emergency flexible calling system consists of GSM module, solar panel, vibration sensor, battery sensor and fire sensor which are connected with centralized control room by wireless communi...

Power Tracing And Loss Allocation In A Power System By Using Bialek’s Algorithm

In electric power system a fair transmission pricing scheme is an important issue. The issue of power tracing helps to evaluate a fair and transparent tariff. A power tracing method would make it possible to charge the g...

Crash Test Simulation and Analysis of a Passenger Bus Frame

Transport buses form an integral part of public transport vehicle fleet in India. A large number of people use public transport buses for their daily conveyance. These buses can be private or government but their safety...

 COMBINED METHODOLOGY of the CLASSIFICATION RULES for MEDICAL DATA-SETS

 ‘Data mining’ offers methodological and technical solutions to deal with the analysis of medical data and construction of prediction models. A large variety of these methods requires general and simple guidelines...

 Evaluation and Optimization of Machining Parameter for turning of EN 8 steel

 This study used for optimization and evaluation of machining parameters for turning on EN8 steel on Lathe machine. This study investigates the use of tool materials and process parameters for machining forces for...

Download PDF file
  • EP ID EP136181
  • DOI -
  • Views 103
  • Downloads 0

How To Cite

Mohammad Parsaei Maram, Dr. K Rama Mohana Rao (2013). Effect Of Location Of Lateral Force Resisting System On Seismic Behaviour Of RC Building. INTERNATIONAL JOURNAL OF ENGINEERING TRENDS AND TECHNOLOGY, 4(10), 4598-4603. https://europub.co.uk./articles/-A-136181