Effect of Partial Shrouds on the Performance and Flow Field of a Low Speed Centrifugal Compressor
Journal Title: UNKNOWN - Year 2015, Vol 4, Issue 1
Abstract
The performance of a centrifugal compressor without and with partial shroud (PS) attached to the rotor blade tip at three values of tip clearance, viz. =2.2%, 6.1% and 7.9% of rotor blade height at the exit. The rotor exit flow is measured using a precalibrated five hole probe at three flow coefficients, namely, =0.18 (below design flow coefficient), =0.28 (design flow coefficient) and =0.34 (above design flow coefficient). The axial distribution of total pressure coefficient at rotor exit for the three flow coefficients clearly indicate increase in total pressure in the rotor tip region for the configuration with PS compared to that for the basic configuration. Similar increase is observed in the static pressure distribution at the rotor exit for the higher values of clearance. The mass averaged total and static pressures at the rotor exit for both configurations at the three values of tip clearances clearly show that partial shrouds are beneficial in improving the pressure rise of the compressor. This benefit is found to be more at the higher value of tip clearance tested.
Developer SQL Scripts to Upgrade Database Schema
As life cycle of any software product does not remain same for long time because as time passes we required certain modification in existing product. In software database product it is difficult to do modification becaus...
To Compensate AC loads using DSTATCOM
DSTATCOM is very popular in compensating the linear, nonlinear, balanced and unbalanced loads. Any change in the load affects the DCLV directly. The proper operation of DSTATCOM requires variation of the DCLV within the...
Assessment of Bacteriological Quality of Drinking Water in Srikakulam District
"Water is one of the indispensable resources for the continued existence of all living Things including man, however in recent periodconsumption of drinking water contaminated with faecal originated pathogenic bacteria h...
Design and Implementation of Parallel CRC for High Speed Application
"High speed data transmission is the current scenario in networking environment. Cyclic redundancy check(CRC) is essential method for detecting error when the data is transmitted. With the challenging speed of tran...
Teachable Moments: A Tool for Improving Learner’s Learning in Depth and Breath
Paper attempts to bring the idea of teachable moments to be a serious part of school teaching. Teachable moments are unplanned seized opportunities for teaching important aspects related to learning contents, social and...