Effect of Thermal and Mechanical Cycles on the Hardness and Roughness of Artificial Teeth
Journal Title: International Journal of Dentistry and Oral Science (IJDOS) - Year 2015, Vol 0, Issue 2
Abstract
Aims: In this study the effects of thermal and mechanical cycles on the hardness and roughness of artificial teeth were evaluated. Materials and Methods: Specimens were prepared and stored in distilled water at 37ºC for 48 hours (n=10). The hardness and roughness readings were made in the following time intervals, according to each group:G1: after specimen storage in distilled water at 37°C for 48 hours; G2: after 600.000 constant mechanical cycles; G3: after 1.200.000 constant mechanical cycles; G4: after 2.500 thermal cycling baths, alternated between hot water (55°C) and cold water (5°C) and G5: after 5.000 thermal cycling baths, alternated between hot water (55°C) and cold water (5°C). After cycling and storage procedures, the specimens of each group were submitted to surface roughness and hardness readouts. Statistical evaluation was performed by three-way analysis of variance, complemented by the Tukey multiple comparisons of means test. The level of significance adopted was 5%. There was no significant difference between G1, G4 and G5 as regards mean roughness of different brands of artificial teeth. Groups G2 and G3 showed higher mean roughness values, and generally equivalent values in all time intervals, except for Trilux (G3> G2). Significant differences in hardness values were observed in different brands of artificial teeth, and differences in values after thermal and mechanical cycling. In conclusion, our findings suggest that thermal cycling did not change the roughness of the artificial teeth tested, but after the mechanical cycling the roughness values increased. Thermal and mechanical cycling influenced the hardness of the artificial teeth tested.
Authors and Affiliations
Janaina Habib Jorge
Influence of Ceramic Laminate Veneer Thickness on Sorption and Solubility of Light-Cured Resin Cement
Objective: This study evaluated the influence of different thicknesses of ceramic laminate veneers on water sorption and solubility of light-cured resin cement. Materials and Methods: Twenty-four specimens of light-cure...
3D Soft Tissue Imaging: An Accurate and Economical Approach
Research work regarding 3 dimensional (3D) soft tissue imaging is very scarce, the reason behind that is that 3D imaging modalities are either invasive, or expensive, or lack accuracy to a great extent. Aim of the study:...
Light Emitting Diode in Comparison to Halogen Curing Technology: Microshear Bond Strength of Dental Composite Resin Restorative Material
The aim of this study was to compare the micro-shear bond strength of composite resin cured with halogen visible light and blue light emitting diode curing units. Flat enamel surfaces of 50 segments of teeth were prepare...
Knowledge of Risks Associated with Dental Implants Failure
Purpose: This paper presents the results of a survey of dentists practicing implant dentistry regarding their knowledge of risk factors that they considered to be important for predicting dental implant failure. Material...
Main Considerations On The Exostosis and Torus: Brief Review
Patients with exostosis (bony nodules on the vestibular face of the mandible bone) and mandibular torus (bony nodules on the lingual face of the mandible bone) frequently present in bruxism, but not all patients with bru...