Effectiveness of Continuous Passive Motion in Hemiarthroplasty of Hip

Journal Title: Journal of Medical Science And clinical Research - Year 2018, Vol 6, Issue 2

Abstract

Background: Continuous passive motion (CPM) is often used in the early post-operative rehabilitation of patients after hip surgery. Aim of this study was to evaluate the effectiveness of new CPM device after hemi arthroplasty in terms of clinical scores and functional recovery. Materials & Methods: A total of 26 patients undergoing hemiarthroplasty were assigned into two groups. The experimental group received continuous passive motion and conventional physiotherapy and control group received only conventional physiotherapy for seven days as tolerated. Results: Average difference in active range of hip abduction was 25 ±5 degrees and Oxford hip score difference was 5.7 ± 3.5 in control group that received conventional physiotherapy. On the other hand, average difference in active range of hip abduction was 40 ±10 degrees and Oxford hip score difference was 8.8 ± 3.6 in experimental group that received an additional intervention in form of continuous passive motion. Conclusion: Continuous passive motion machine can be used as an adjunct to conventional physiotherapy after hemiarthroplasty

Authors and Affiliations

Harne MS

Keywords

Related Articles

Comparative study of Voluntary and Replacement blood donors from Blood Bank, Chamba (H.P)

Introduction: Voluntary blood donation is undoubtedly, the greatest service to mankind as it can save many precious lives every single day. One single blood donation can help many patients as blood is usually segregated...

Hepatitis B Virus Vaccination Status and Knowledge about Hepetitis B Infection among Health Care Workers of Katihar Medical College, Bihar

Background: Hepatitis B (HB) is a global Public Health Problem infecting nearly 2 billion people around the globe. Health care workers are at risk of acquiring HBV, HCV, and HIV infections via exposure to patient’s blood...

Study of Prevalence of Various Cutaneous Manifestations Inchildren Suffering from Severe Acute Malnutrition (SAM)

Aims and Objectives: To study prevalence of various cutaneous manifestations in children suffering from severe acute malnutrition (SAM) in the age group of 6 months to 5 years over a period of 6 months. Study Design: It...

Use of Rubber Band Ligation and Micronized Flavanoid in the Treatment of Hemorrhoid: A Comparative Study

Background: Hemorrhoid is a common cause of per rectal bleeding of all sexes. There are many options for the management of hemorrhoid depending on symptoms and degree of hemorrhoids. Rubber band ligation and micronised f...

A Study of Salivary and Serum Lactate Dehydrogenase Levels in Tobacco Users and Potentially Malignant Disorders

Aim: To measure and compare the LDH levels in serum and saliva in tobacco users and potentially malignant disorders. Materials And Methods: Thirty subjects were recruited for this study and divided into three groups, 10...

Download PDF file
  • EP ID EP502722
  • DOI -
  • Views 64
  • Downloads 0

How To Cite

Harne MS (2018). Effectiveness of Continuous Passive Motion in Hemiarthroplasty of Hip. Journal of Medical Science And clinical Research, 6(2), 327-331. https://europub.co.uk./articles/-A-502722