Effects of Temperature and Humidity on Laser Diffraction Measurements to Jet Nebulizer and Comparison with NGI

Journal Title: AAPS PharmSciTech - Year 2016, Vol 17, Issue 2

Abstract

Laser diffraction (LD) and next generation impactor (NGI) are commonly used for the evaluation of inhaled drug formulations. In this study, the effect of temperature and humidity on the assessment of the nebulizer particle size distribution (PSD) by LD was investigated, and the consistency between NGI and LD measurements was evaluated. There was an increase in particle size with higher temperature or lower humidity. The particle population with a diameter less than 1 μm was significant at a temperature of 5°C or at relative humidity >90%; however, the same particle population became undetectable when temperature increased to 39°C or at relative humidity of 30–45%. The results of the NGI and LD measurements of aerosol generated from three types of jet nebulizers were compared. A poor correlation between the NGI and LD measurements was observed for PARI LC (2.2 μm) (R 2 = 0.893) and PARI LC (2.9 μm) (R 2 = 0.878), while a relatively good correlation (R 2 = 0.977) was observed for the largest particle size nebulizer (PARI TIA (8.6 μm)). We conclude that the ambient environment and the nebulizer have significant impacts on the performance and consistency between these instruments. These factors should be controlled in the evaluation of inhaled aerosol drug formulations when these instruments are used individually or in combination.

Authors and Affiliations

Xinghan Song, Junhua Hu, Shuyao Zhan, Rui Zhang, Wen Tan

Keywords

Related Articles

Effect of Hydroxyl Groups and Rigid Structure in 1,4-Cyclohexanediol on Percutaneous Absorption of Metronidazole

In a previous study, a synergistic retardation effect of 1,4-cyclohexanediol and 1,2-hexanediol on percutaneous absorption and penetration of metronidazole (MTZ) was discovered. A complex formation between 1,4-cyclohexan...

Development of Duloxetine Hydrochloride Loaded Mesoporous Silica Nanoparticles: Characterizations and In Vitro Evaluation

The online version of this article (doi:10.1208/s12249-014-0273-x) contains supplementary material, which is available to authorized users.

Neem Gum as a Binder in a Formulated Paracetamol Tablet with Reference to Acacia Gum BP

This study determined the physical, compressional, and binding properties of neem gum (NMG) obtained from the trunk of Azadirachta indica (A Juss) in a paracetamol tablet formulation in comparison with official Acacia gu...

Nanomicellar Topical Aqueous Drop Formulation of Rapamycin for Back-of-the-Eye Delivery

The objective of this study was to develop a clear, aqueous rapamycin-loaded mixed nanomicellar formulations (MNFs) for the back-of-the-eye delivery. MNF of rapamycin (0.2%) was prepared with vitamin E tocopherol polyeth...

Disintegration Mediated Controlled Release Supersaturating Solid Dispersion Formulation of an Insoluble Drug: Design, Development, Optimization, and In Vitro Evaluation

The objective of this study was to develop a solid dispersion based controlled release system for drug substances that are poorly soluble in water. A wax-based disintegration mediated controlled release system was design...

Download PDF file
  • EP ID EP682157
  • DOI  10.1208/s12249-015-0346-5
  • Views 87
  • Downloads 0

How To Cite

Xinghan Song, Junhua Hu, Shuyao Zhan, Rui Zhang, Wen Tan (2016). Effects of Temperature and Humidity on Laser Diffraction Measurements to Jet Nebulizer and Comparison with NGI. AAPS PharmSciTech, 17(2), -. https://europub.co.uk./articles/-A-682157