Effects of the grid disturbances on Current Source Rectifier controlled by FCS-MPC algorithm
Journal Title: Power Electronics and Drives - Year 2018, Vol 2018, Issue 1
Abstract
Nowadays, the increasing number of nonlinear loads influence the grid causing grid voltage disturbances. Those disturbances may be very dangerous for the equipment and can create faults in converters behavior. However, the right control algorithm can improve the reliability of the work. For Current Source Rectifier the finite control set model predictive control has been proposed. This method is very flexible because of the variety of the possible cost function forms. It has been examined under grid voltage disturbed by the higher harmonics and the voltage drop. Simulation results prove the ability to damp the distortions and to ensure the unity power factor. Summing up, the algorithm is a very good solution in use in applications such as: battery charging, active power filtering, low voltage DC loads feeding.
Authors and Affiliations
Agata Godlewska
FINITE-ELEMENT ANALYSIS OF ACCIDENTAL ENERGIZING OF AN OFF-LINE TURBOGENERATOR
Background: Presented article shows the computation results of accidental off-line turbogenerator energizing. Inadvertent energizing of turbogenerator has been a particular issue in the power plant. The investigated case...
PMSM Servo-Drive Fed by SiC MOSFETs Based VSI
The article presents modern PMSM servo-drive with SiC MOSFETs power devices and microprocessor with ARM Cortex core. The high switching frequency is obtained due to the application of high efficient power switching compo...
DC LINK CONDITION MONITORING METHOD FOR TWO-LEVEL AC/DC/AC CONVERTERS
Background: Power electronics is one of the most important elements of today’s industry. Many of converters applications are being considered as critical for plant production process. Offering enhanced functionality in m...
Stability analysis of MRASCC speed estimator in motoring and regenerating mode
Background: This paper deals with the stability analysis of MRAS current speed estimator in a motoring and regenerating mode. The problem of unstable operating points of the estimator, mainly in a regenerating mode are w...
A MULTILEVEL SWITCHED CAPACITOR DC-DC CONVERTER. AN ANALYSIS OF RESONANT OPERATION CONDITIONS.
Background: This paper presents the research results of a multilevel switched capacitor DC-DC converter (MLSCC). The converter, for power electronic applications, can operate in ZCS mode by utilizing resonant circuits fo...