Efficacy of Amnitear vs. Conventional Method for Artificial Rupture of Membranes: A Prospective Study

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 6

Abstract

ABSTRACT Introduction: Amnitear is a newer device which is to be worn over gloved index finger for doing artificial rupture of membranes. Aim: To evaluate the efficacy of Amnitear in doing Artificial Rupture of Membrane (ARM) and to compare the efficacy and safety of amnitear Vs the conventional method (kocher’s clamp) in ARM. Material & Methods: A prospective, single-blinded, randomized study was done to evaluate the efficacy of Amnitear Vs conventional method (kocher’s clamp) for doing ARM. Patients with even Inpatient Department (IPD) number were grouped as ‘A’ (study group) in which ARM was done with amnitear & Group ‘K’ (control group) constituted the patients with odd IPD number in which ARM was done with conventional method (kocher’s clamp). There were 60 patients in each group. Obstetrician comfort level was assessed by the experience felt by the concerned doctor; in terms of excellent, good and poor. Pain and discomfort felt by the patient during the procedure was assessed with the help of visual analogue scale scoring system. Results: One hundered and twenty women in labour requiring ARM were randomized into 2 groups. The efficacy of Amnitear was assessed in terms of number of attempts required to successfully perform the procedure which showed a statistical significant difference (p=0.02) in the two groups. Obstetrician comfort level was significantly better in amnitear group. No statistically significant difference was seen in the pain and discomfort felt by the patient during both the procedure. Conclusion: Amnitear appears to be an efficacious device to do the ARM.

Authors and Affiliations

Nidhi Gupta, Aruna Nigam, Neha Varun, Snehlata Meena, Rashmi Aggarwalla

Keywords

Related Articles

A Review of Knowledge and Attitudes Towards Dementia Among College and University Students

Introduction: Dementia is pressing problem for family and society. Next generation health care providers which are current healthcare program students are important part of professional caregiving system in future. Parti...

Assessment of Correlation between Carotid Artery Calcification and Alveolar Bone Loss: A Retrospective Study of CBCT Findings

ABSTRACT Introduction: One of the main causes of the cardiovascular diseases is atherosclerosis which is characterised by thickening and the loss of elasticity of the arterial walls. Chronic periodontitis is one of the r...

Validation of Hemochroma PLUS: A Point of Care Testing Device for Haemoglobin Estimation

ABSTRACT Introduction: Anaemia is a major public health challenge in India. Advent of Point of Care (POC) testing devices for haemoglobin estimation may be useful in the field settings, albeit after proper validation of...

Relative Leg Length as a Risk Factor for Hypertension and Diabetes in Egyptian Adults

ABSTRACT Introduction: Studies from developed societies have shown that individuals with short legs relative to height have higher risk of association with the components of the metabolic syndrome such as glucose intoler...

Effect of Green Coffee Bean Extract on Streptococcus mutans Count: A Randomised Control Trial

Introduction: Mouth rinses have been popularly used as a supplementary oral hygiene aid. A lot of commercially available mouth rinses possess few adverse effects, which has necessitated the search for alternative and her...

Download PDF file
  • EP ID EP524501
  • DOI 10.7860/JCDR/2018/32304.11617
  • Views 67
  • Downloads 0

How To Cite

Nidhi Gupta, Aruna Nigam, Neha Varun, Snehlata Meena, Rashmi Aggarwalla (2018). Efficacy of Amnitear vs. Conventional Method for Artificial Rupture of Membranes: A Prospective Study. Journal of Clinical and Diagnostic Research, 12(6), 18-20. https://europub.co.uk./articles/-A-524501