Energy Audit of Health Care Facilities: Dynamic Simulation of Energy Performances and Energy-Oriented Refurbishment of System and Equipment for Microclimatic Control
Journal Title: American Journal of Engineering and Applied Sciences - Year 2016, Vol 9, Issue 4
Abstract
Abstract Topic of the study is the investigation of potentialities of energy simulation for optimizing the building refurbishment, by taking into account impacts of both envelope renovation and HVAC system selection. Energy audit and refurbishment of the Day-Hospital building of a great Italian health care facility are proposed. A meticulous energy diagnosis of the base case building and design of a complete renovation- by improving both building envelope and HVAC systems- are presented. All data and boundary conditions for dynamic energy investigations have been carefully selected, also by means of in-situ studies, in order to provide a reliable model. In particular, several energy efficiency measures, with reference to building envelope and HVAC systems, are analyzed and it will be evidenced that, step-by-step, a proper design, supported by the adoption of numerical studies, may optimize the energy performances of the building, as well as the indoor microclimatic control. Copyright © 2016 Fabrizio Ascione, Nicola Bianco, Rosa Francesca De Masi, Filippo de Rossi, Claudio De Stasio and Giuseppe Peter Vanoli. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Authors and Affiliations
Fabrizio Ascione, Nicola Bianco, Rosa Francesca De Masi, Filippo de Rossi, Claudio De Stasio, Giuseppe Peter Vanoli
Testing by Non-Destructive Control
Abstract This paper describes an application of industrial robots that gain ground mainly in the aerospace industry. It is a TTT manipulator whose task is to automatically position the end-effector, in this case a compl...
Biodegradation of 2, 4 Dichlorophenol
Abstract The present study focuses on the optimization of process parameters of the aerobic biodegradation of 2, 4 Dichlorophenol (2, 4 DCP) by a commercial strain of P. putida immobilized in PVA gel matrix, using desig...
Advanced XFEM Simulation of Pull-out and Debonding of Steel Bars and FRP-Reinforcements in Concrete Beams
Abstract An innovative three-dimensional model is applied to the pull-out of steel bars and the debonding of FRP plates from concrete specimens. The shearing and opening modes at the interface of debonding is fully capt...
Some Proposed Solutions to Achieve Nuclear Fusion
Some Proposed Solutions to Achieve Nuclear Fusion Relly Victoria Virgil Petrescu, Aversa Raffaella, Samuel Kozaitis, Apicella Antonio and Florian Ion Tiberiu Petrescu DOI : 10.3844/ajeassp.2017.703.708 American Journal...
Probabilistic Seismic Hazard Deaggregation for Karaj City (Iran)
Abstract In this study the results of PSHA deaggregation for 5%-damped 0.2, 0.5, 2 and 4 s spectral accelerations, corresponding to Mean Return Periods (MRPs) of 50 and 475 yr for Karaj city was presented. The aim of th...