Energy Harvesting: A Toxic Free and Reliable Power Source for Implantable Microsystems

Abstract

The implantable medical devices require constant power source and for this requirement, batteries have been developed that has enabled the successful deployment of the devices and their treatment of human disease. While the functional requirements for the batteries used to power these devices vary with the type of device and therapy, there are some characteristics that are demanded by all applications. The batteries must have high life span, be safe during installation and use, have predictable performance that can be interrogated to provide state of discharge information and be highly reliable [1]. Additionally, the batteries must have high volumetric energy density to enable the design of small devices that minimize discomfort for the patient. Thus, long term stability during use, predictable performance, high volumetric energy density and outstanding reliability are key characteristics that define successful systems for biomedical implants [1]. Since the introduction of first cardiac implant in 1972, a variety of battery systems have been developed for implantable medical devices that utilize lithium metal anodes with cathode systems including iodine (Li/I2) [2-4], manganese oxide (Li/MnO2) [5,6], carbon monofluoride (Li/CFx) [7,8], silver vanadium oxide (Li/SVO) [9,10] and hybrid cathodes using both carbon monofluoride and silver vanadium oxide (Li-CFx-SVO) [11,12]. The specification of these batteries is presented in Table 1. This range of batteries provides the appropriate power levels as demanded by a specific medical device varying from microampere to ampere level currents. Successful development and implementation of these battery types has helped enable implanted biomedical devices and their treatment of human disease. Among these, Li/I2 has proved to be safer and more reliable than others for use in pacemakers and hence used widely in the last 4 decades [13]. However, these batteries suffer from limited life span and hence require replacement by surgery which is inconvenient to the patient. Hence an alternate energy source is required to continuously power these implants. One such approach which can address the abovementioned problem is Energy Harvesting [14,15]. It is the process of scavenging out energy from different sources in the ambient environment. Various harvesters are being proposed to harvest energy for implantable devices. Some of the recently reported harvesters can be studied in [15-21]. The form of energy used by the harvester to scavenge the power, defines the type of energy harvesting. There are four main ambient energy sources available viz., mechanical energy due to vibrations and deformations (electrostatic, piezoelectric and electromagnetic), thermal energy (temperature variations and gradients), radiant energy (sun, IR, RF) and biochemical (bio-fuel cells). A comparison of the power densities of these different energy sources is presented in Figure 1 [15,22].

Authors and Affiliations

Suhaib Ahmed, Vipan Kakkar

Keywords

Related Articles

Treatment of Scaphoid Waist Non-Union with A ModifiedMatti-Russe Technique: Our Experience Giuseppe

Background: Amongst the different techniques for scaphoid non-union, the Matti-Russe procedure is a simple method where a corticocancellous bone graft from the iliac crest is packed in the scaphoid. A variant of the tech...

Henry Dyer Remembers: A Social History of Old Lautoka and Namoli Village, Fiji, 1962-2000

This section discusses the restaurants and nightlife of Old Lautoka City, Fiji Islands, in the 1960s through to the 1990s, as recalled by the ex-Nadi and Fiji soccer champion Henry Dyer Tuidraki in interview with Kieran...

Clinically Beneficial Application of Flash Glucose Monitoring (FGM)

For the treatment of diabetes, it is important to manage glucose variability and to prevent microvascular complications as well as long-term macrovascular disease [1]. HbA1c has been the gold standard for monitoring gluc...

Beta-Ketothiolase Deficiency as A Treatable Neurometabolic Disorder: A Case Report Due to A Novel Compound Heterozygote Mutations in ACAT1 Gene

Mitochondrial 2-methylacetoacetyl-CoA thiolase deficiency (OMIM#203750, *607809) is a rare inherited disorder of isoleucine amino acid catabolism and ketone body metabolism. Clinical manifestations of this disorder a...

Resection of Giant Hepatocellular Carcinoma: Case Report

Huge hepatocellular carcinoma (>10cm) resection it is not frequent in cirrhotic livers due to high mortality rates and poor survival rates. Nevertheless, patients with normal livers have a different prognosis, and can be...

Download PDF file
  • EP ID EP581030
  • DOI 10.26717/BJSTR.2017.01.000454
  • Views 174
  • Downloads 0

How To Cite

Suhaib Ahmed, Vipan Kakkar (2017). Energy Harvesting: A Toxic Free and Reliable Power Source for Implantable Microsystems. Biomedical Journal of Scientific & Technical Research (BJSTR), 1(5), 1426-1428. https://europub.co.uk./articles/-A-581030