Estimation of platelet counts: auto analyzer versus counts from peripheral blood smear based on traditional and platelet: red blood cell ratio method

Abstract

Introduction: Accurate platelet counts are of utmost importance in clinical practice The methods used for estimating platelet count are: Manual method using counting chamber, Examination of a peripheral blood smear (PBS) and automated hematology analyzers Automated hematology analyzers produce erroneous results in the presence of particles of similar size and/or light scatter like fragmented red blood cells (RBC), microcytic RBCs and in the presence of giant platelets and platelet clumps. Aims and Objectives: Comparison of platelet count by three methods: 1. Automated six part analyzer. Traditional method: Counting average platelets per ten high power fields and multiplying the same by 15,000. 3. From smear by counting the number of platelets per 1000 RBCs and calculating the platelet count on the basis of platelet: RBC ratio. Methods: Ethylene Diamine Tetra-acetic acid (EDTA) samples for platelet counts over a period of two months were analyzed by the above-mentioned methods. Statistical software SPSS 2 and independent T tests were used to compare the variables between the groups. Sensitivity and specificity of the methods was calculated. Results: 250 EDTA samples were analyzed of which normal platelet counts were (56.4%) thrombocytopenic (35.2%) and thrombocytosis (8.4%). There was no significant difference between the platelet counts done by the auto analyzer compared with traditional (P value 0.50) and platelet: RBC ratio method (0.906). Specificity of the methods was 99.1% and the sensitivity was 92.5%. Conclusion: Platelet counts by traditional and platelet: RBC ratio can be used as alternate reliable methods as compared to the auto analyzers.

Authors and Affiliations

Akhila Balakrishnan, Archana Shetty, Vijaya C,

Keywords

Related Articles

A study on ESKAPE pathogens the bad bug with no drug

Introduction: ESKAPE pathogens include Enterococcus faecium, Staphylococcus aureus, Klebsiella pnuemonia, Acienetobacter baumanii, Pseudomonas aeruginosa and Enterobacter species. Currently all these organisms are the ma...

To evaluate efficacy of FNAC in diagnosis of cystic lesions in paediatric age group patients- A retrospective study in a tertiary care teaching hospital

Introduction: Fine Needle Aspiration Cytology is a rapidand economical mode of preoperative diagnosis. It has early availability of results & simple procedure with minimal trauma and complications but it has limited lite...

Evaluation of diagnostic accuracy of FNAC and correlation with histopathology in thyroid lesions

Aim: The aim of the study is to evaluate the accuracy of FNAC diagnosis in non neoplastic & neoplastic lesions of thyroid, and correlating with histopathological findings. Materials and Methods: This was a prospective st...

An extensive study: to assess the changing trends in prevalence and development of TTIs in non-remunerated blood donors at a tertiary care teaching hospital in Central India

Background: Transfusion transmitted infections (TTI) are a major challenge to the transfusion services all over the world. The problem of TTIs is directly proportionate to the prevalence of the infection in the blood don...

Evaluation of GeneXpert MTB/RIF assay in diagnosis of extra pulmonary tuberculosis and rifampicin resistance

Background: The prevalence of tuberculosis is still on the rise particularly extrapulmonary cases. There is an urgent need for rapid diagnosis of these cases for prompt initiation of treatment. Aim: To evaluate the role...

Download PDF file
  • EP ID EP498623
  • DOI 10.17511/ jopm. 2018.i5.04
  • Views 115
  • Downloads 0

How To Cite

Akhila Balakrishnan, Archana Shetty, Vijaya C, (2018). Estimation of platelet counts: auto analyzer versus counts from peripheral blood smear based on traditional and platelet: red blood cell ratio method. Pathology Update: Tropical Journal of Pathology and Microbiology, 4(5), 389-395. https://europub.co.uk./articles/-A-498623