Evaluation and Comparision of Biomechanical Properties of Different Loops for En Masse Retraction of Anterior Teeth Using Finite Element Analysis: An In-Vitro Study.

Abstract

Background: To evaluate and compare the biomechanical properties of various retraction loops using Finite Element Method. Materials and method: Using Finite element method (Ansys V15 software) 25 loops were constructed with 0.016×0.022 inch stainless steel and 0.017×0.025 inch titanium molybdenum wire. Results: The M/F ratio produced was higher and F/D rate produced was least for Opus loop compared to Snail loop, Teardrop loop, T-loop, and Teardrop with helix loop. Conclusions: For optimum delivery of M/F ratio using snail loop must be prepared in either 0.016×0.022 SS wire with preactivation bend of 10° after D2 displacement or 0.017×0.025 TMA wire with preactivation bend of 10° and 20° after D1 displacement.

Authors and Affiliations

Dr. Pooja Gunjal

Keywords

Related Articles

Evaluation of Leptin Levels in Gingival Crevicular Fluid during Orthodontic Tooth Movement.

Objectives: To test if leptin can be detected in the gingival crevicular fluid (GCF) and to determine whether any changes occur during orthodontic tooth movement. Materials and Methods: Thirty patients were included in t...

Smile Makeover with Ceramic Laminates – A Solution for the Discolored Teeth.

Discolored teeth cause unaesthetic smile which often lowers the self esteem of a person. There are various reasons for the discoloration of the teeth. Flourosis which is endemic in various parts of world is also one of t...

Improvised Impression Method to Record Defective Maxillary Alveolar Ridge after Tumor Resection Using a Pneumatic Approach, Followed By Total Rehabilitation: a Case Report.

Purpose: To record maxillary alveolar ridge defect area following tumour resection using inflated balloon loaded with impression material, to achieve an improvised result. Method: A case of maxillary alveolar ridge defec...

Surgical Management of Fractured Miniscrew.

Absolute anchorage provided by miniscrew play important role in success of treatment. Failure of anchorage unit leads to compromised treatment outcome. In this case report, surgical management of fractured miniscrew in t...

Evaluation of salivary antioxidants – Superoxide Dismutase and Glutathione Peroxidase in OSMF patients and healthy individuals – A comparative study.

Background: Saliva is the first biological medium that is encountered during chewing. Saliva provides a natural defence against harmful substances and microorganisms. Research confirms that antioxidants are among the mos...

Download PDF file
  • EP ID EP578605
  • DOI -
  • Views 85
  • Downloads 0

How To Cite

Dr. Pooja Gunjal (2019). Evaluation and Comparision of Biomechanical Properties of Different Loops for En Masse Retraction of Anterior Teeth Using Finite Element Analysis: An In-Vitro Study.. International Journal of Dental Science and Innovative Research (IJDSIR), 2(2), 443-449. https://europub.co.uk./articles/-A-578605