Evaluation of Bacillus Subtilis Bacterial Concrete with Normal Concrete

Journal Title: IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) - Year 2018, Vol 15, Issue 5

Abstract

Concrete is a most commonly used material in the field of construction with high compressive strength but with low tensile strength. The advantage of concrete is that it is easily available, less costly and convenient to cast. Concrete structures are very susceptible to cracking which causes chemicals and water to penetrate in the concrete that degrades the concrete strength, thereby, decreasing the performance of the structure. To solve this problem, eco-friendly concrete is developed. This concrete is formed by inserting bacteria into normal concrete. The grown bacteria are added to the M-25 concrete. The main motive of this research work is to measure the performance of the concrete by the microbiologically induced unique growth or filler. One such contemplation has lead to the improvement of a very unique concrete known as Bacterial Concrete where bacteria is induced in the cement and concrete to heal up the cracks. In this research, numbers of tests are performed on normal concrete and bacterial concrete for 7, 14, and 28 days. To determine the accuracy of the bacterial concrete, parameters such as water absorption, compressive strength, Ultrasonic pulse velocity test (UPVT), Flexural test and slump test are measured.

Authors and Affiliations

Er. Simranjit Singh Raina, Er. Sandeep Singla, Dr. VS Batra

Keywords

Related Articles

Earthquake Effects To Partially Dismantled Building

This study carries out the comparative study of Seismic Performance of residential buildings after partial dismantling for road widening works in Kathmandu city. Two types of buildings were taken for the study i.e. 4 sto...

Study of Using Sum to Improve Digital Archives Integrity of Traditional Architectures with 3D Laser Scanning Technology

3D laser scanning technology has been widely applied to digital archive and management of historical buildings, and that is enormous contributions for human civilization inherited. But the technology is limited by comple...

Evaporation Control Technique in Open Reservoirs: An Overview and Assessment Study

Global warming and the increasing concentration of greenhouse gases in the atmosphere will affect temperature and rainfall.This rise in temperature ultimately results in evaporation losses from storage reservoirs. As wat...

Road Defects and Highway Maintenance

This paper summarizes the ongoing researches about the defects in Flexible and Rigid pavement and the maintenance in Flexible and Rigid pavements. In the past, lots of researchers have already studied the defects and pro...

Mechanical Properties of Concrete Using Optical and Glass Fibre

Concrete has been used since Roman times for the development of infrastructure and housing, but its basic components have remained the same. Three ingredients make up the dry mix: coarse aggregate, consisting of larger p...