Evaluation of pulmonary functions in petrol pump workers
Journal Title: Indian Journal of Clinical Anatomy and Physiology - Year 2016, Vol 3, Issue 2
Abstract
Introduction: Petrol/ Diesel vapour generates pollutants like hydrocarbons, oxides of nitrogen, carbon and particulate matter. Occupational exposure to petrol/ diesel vapours have been shown to affect the functioning of different systems of the body. Hence the present study aims to evaluate the pulmonary functions in petrol-pump workers. Aim: Aim of the present study is to evaluate the pulmonary functions in petrol-pump workers and to compare their Pulmonary function tests (PFTs) with that of age and sex matched controls. Methodology: Study group- Fifty healthy, non-smoker petrol-pump workers in the age group of 18-40 years. Control group-Fifty age and sex matched healthy nonsmokers. The pulmonary function tests Forced vital capacity (FVC) and Vital capacity (VC) were carried out by using computerized spirometer. The parameters Peak Expiratory Flow Rate (PEFR (L/S)) Forced Expiratory Flow (FEF25&75%(L/S), Peak Inspiratory Flow (PIF(L/S), Forced Vital Capacity (FVC(L) Forced Expiratory Volume in first second (FEV1(L)), Forced Expiratory Volume percentage(FEV1%), Forced inspiratory vital capacity (FIVC(L)), Vital capacity (VC(L)), Expiratory reserve volume (ERV(L)) were compared between the two groups. Results: The PFTs of petrol pump workers were significantly decreased as compared to controls. The female workers and controls had significantly lower PFT than their respective male counterparts. The male petrol pump workers with more than 5 years of exposure had significantly decreased PFT. Discussion: The decreased lung functions in petrol-pump workers may be attributed to their exposure to the volatile organic compounds like Benzene, pollutants like Lead, CO, CO2, Nitrogen oxides, Sulphur oxides ,Hydrocarbons and unburned carbon particles for more than six months, for at least 10 hours per day. The comparatively increased PFTs in males than females may be attributed to the greater inspiratory muscle strength, more number of alveoli per unit area, larger alveoli and greater compliance in males. Decreased PFT in workers with more than five years of service indicate that the decrements in pulmonary functions are worsened by increased years of exposure.
Authors and Affiliations
Sumathi P, N. Neelambikai
A cadaveric study of coronary arteriesin Rayalaseema population of Andhra Pradesh
Introduction Majority of the sudden cardiac deaths were due to anomalous origin and distribution of the coronary arteriesAim To study the arterial vascular pattern of the human heart by using dissection method in Rayalas...
Morphometric study of medial menisci of the adult knee joint
Introduction: Knee joint is the largest articulation in the body. The condyles of the femur rest in unequal manner on the shallow concave surface of the tibia. The menisci are firmly attached to the intercondylar area of...
Serum testosterone as predictor of pathological stage in prostate cancer
Aim: The aim of our study is - To assess whether parameter as serum testosterone can be used to predict the pathological stage of the disease. To determine whether serum testosterone can be used as prognostic marker for...
A cadaveric study of variations in the branches of popliteal artery in South Indian population
Introduction Popliteal artery gains much importance because of the clinical conditions encountered and the surgeries carried out in the region of popliteal fossa The variations in the branching pattern of popliteal arter...
Biochemical evaluation of vitamin D levels in pre diabetes, type 2 diabetes mellitus and its correlation with glycated hemoglobin
Introduction Globally 1 billion people are suffering with deficiency or insufficiency of vitamin D Vitamin D deficiency is also associated with metabolic disorders This study evaluates Vitamin D levels in prediabetes T2D...