Evaluation of Radiation Dose Received By Patient during Cardiac Catheterization Procedure

Journal Title: International Journal of Science and Research (IJSR) - Year 2015, Vol 4, Issue 3

Abstract

The current study intends to measure patient dose and estimate the radiation dose received for patient in (IC) procedures. The study was measured radiation doses to (212) patients during interventional cardiology procedures 161to coronary angiography (CA) and 51 to percutaneous coronary interventions (PCI) was carried out in this study patient doses were calculated from patient body characteristics and exposure parameters using dose area product (DAP) meters. The mean age of patients 57.42 ±11.65 was ranging (21to 86) years. The mean value of tube parameter was 86.17 ± 8.32KVp, ranges (to 63 from 105) Kvp, 5.59 ± 0.844mAs range (to 3.2 from 10.2) mAs. The mean duration time of fluoroscopy was 6.87 ± 7.06 mentis and the number of films per procedure was 9.17 ± 4.53 films, range was (3 to33) films. All the investigations were performed in same center and department. The DAP measured in this study was lower than the previous reported studies in the literature. Because they can be attributed to the use of high voltage, long distance between patient and ionizing radiation source in all examinations

Authors and Affiliations

Keywords

Related Articles

Secure Cloud DBaaS by Client and Server side Encryption

Storing confidential data in cloud must provide guarantee of security and availability of the data, even though many alternatives are existed for handling and storing of data, while information confidentiality solution f...

Image Enhancement using Histogram Equalization and Spatial Filtering

Image Enhancement is one of the important requirements in Digital Image Processing which is vital in making an image useful for various applications which can be seen in the areas of Digital photography, Medicine, Geogra...

Stress Analysis of Crane Hook with Different Cross Section Using Finite Element Method

Crane hook is a mechanical component used for material handing or transfer, observes stresses, induced when different kinds of load applied. From the safety point of view the crane hook damaged must be prevented due to c...

Dielectric and AC Conductivity Studies of NaCF3SO3 -PEO Doped Polyaniline Complexes

The polymer electrolyte based on polyethylene oxide (PEO) complexes with conducting Polyaniline (PANI) and Sodium triflate salt (NaCF3SO3) has been prepared in different weight percentage (wt%) by in-situ polymerization...

Ocular Involvement in Connective Tissue Disorders in a Tertiary Hospital

Abstract-Connective tissue disorders are systemic auto immune disorders.Ocular involvement is reported frequently in these diseases.

Download PDF file
  • EP ID EP357929
  • DOI -
  • Views 104
  • Downloads 0

How To Cite

(2015). Evaluation of Radiation Dose Received By Patient during Cardiac Catheterization Procedure. International Journal of Science and Research (IJSR), 4(3), -. https://europub.co.uk./articles/-A-357929