The aim of this study is essentially to evaluate radiation doses to paediatric patients who were referred for chest X-ray examination between April, 2015 and December, 2016 in three hospitals South-West, Nigeria. The methodology employed in this study involved measurements based on the use of exposure parameters to determine Entrance Surface Dose (ESD). A total of one hundred (100) paediatric patients randomly chosen were included in this study. ESD was determined from exposure parameters using dose calculation software (Dosecal). The results of this study show that the range of Entrance Surface Doses (ESDs) obtained for 0-1year patient is 38.00-150.00 µGy, for 1-5 years is 43.34-194.00 µGy, for 5-10 years is 74.00-223.00 µGy and for 10-15 years is 87.60-292.00 µGy. The mean ESDs obtained in this study were found to be relatively lower than the ESDs obtained in other previous studies in Nigeria but higher than the recommended reference dose value given by the European guidelines. This indicates that more attention needs to be given to X-ray facilities in the Country and that X-ray departments need to review their practice in terms of training and re-training of radiographers, repeated chest X-ray procedures for paediatrics, calibration of X-ray machines and standardisation of processing chemicals in order to bring dose given to patients to optimum levels. This study has also revealed the need to have dedicated X-ray facilities for paediatrics throughout the country.
Authors and Affiliations
Osahon O. David, Bamidele Lateef
Dumpsite Characterisation in Ekpoma from Integrated Surface Geophysical Methods
Foreseeable consequences of the practice of solid waste disposal in landfills are gas and leachate generation due primarily to microbial decomposition, climatic conditions and refuse characteristics. Hence, this paper pr...
Characterization of Worst Month Statistics for Satellite-Earth Links Performance in Tropical Locations
The increasing development in satellite technology has brought about several novel mobile satellite services and applications. Consequently, there is a pressing demand for seamless data transfer and accessibility to sate...
Influence of Thickness on the Optical Properties of Cadmium Sulphide Thin Film Deposited by Chemical Bath Deposition Technique
Cadmium Sulphide (CdS) thin films were deposited onto glass substrates by chemical bath deposition (CBD) technique from a bath containing Cadmium acetate, ammonium acetate, thiourea and ammonium hydroxide and the bath wa...
Geophysical Evaluation of a Landfill Site in Ikpoba Okhia Local Government Area, Edo State, Nigeria
Electrical resistivity tomography (ERT) technique has been used in this research to evaluate the contamination zones at a dumpsite in Benin City. Three electrical resistivity profiles were established for the purpose of...
Variability of Microwave Radio Refractivity and Field Strength over Some Selected Locations in Nigeria
In this study, results of the variation of radio field strength derived from the computation of surface refractivity through measurements of temperature, relative humidity and pressure across seven locations ((Akure (7.1...