Abstract

Aims and Objectives- To check the reliability of finger tip palpation of pilot balloon to judge the ETT cuff Pressure, to record the volume required to achieve the ETT cuff pressure of 25 cm H2O. Material and Methods- Total 100 patients of posted for surgery under general anesthesia were studied. After premedication, Inductiondone with inj. Propofol 2 mg/kg, inj. Succinylcholine 2 mg/kg. Female patients will be intubated with 7.0 no cuffed ETT, Male patients will be intubated with 8.0 no. cuffed ETT. ETT cuff will be inflated and cuff pressure was judged by palpation of pilot balloon method. Actual ETT cuff pressure was checked by ETT cuff manometer and recorded. Then the ETT cuff will be inflated by 1 ml incremental inflation of air and the actual air required toget the pressure of 25 cmH2O, and it will be again noted. Results– In 72 % cases ETT cuff pressure was above 30 cm H2O, in 18 % cases cuff pressure was in the recommended range (20-30 cm H2O), in 10% cases it was below 20 cm H2OConclusion– ETT cuff pressure measurement using ETT cuff manometer should be highly recommended as routine method to inflate ETT cuff.

Authors and Affiliations

Manohar Mane, Prashant Lomate, J Paranjape

Keywords

Related Articles

Comparison of intramuscular atropine and glcopyrrolate in children undergoing various surgical procedures under general anaesthesia

Background: Antiocholinergic premedication in paediatric patients undergoing surgeris under general anaesthesia plays in important role in blocking the potentially dangerous vagal reflexes and in also controlling the oro...

Comparative study of supraglottic airway device proseal versus I-gel in mechanically ventilated patients

Background: Laryngeal mask airways (LMA) represent a good alternative to endotracheal intubation in suitable cases. I-gel is more frequently used in patients under general anesthesia and receiving positive pressure venti...

Challenges of managing a post-arrest resuscitated patient for urgent CABG and concomitant non-cardiac surgery under same anaesthesia

Background: Coronary artery disease is a leading cause of morbidity and mortality.2016 Heart disease and Stroke Statistics of AHA reported 15.5 million people more than 20 years in USA have CAD, number increasing with ag...

A comparative study of haemodynamic and electrolyte changes between 1.5% Glycine and distilled water as irrigation fluid for transurethral resection of prostate surgeries

This prospective comparative study was conducted to study and compare the perioperative haemodynamic and electrolyte changes when 1.5% Glycine and sterile distilled water is used as an irrigation fluid for transurethral...

A comparative study of Dexmedetomidine versus midazolam with fentanyl for monitored anaesthesia care in tympanoplastyunder local anaesthesia

Background and Aims: Monitored anaesthesia care (MAC) is a procedure in which the local anaesthesia(LA) and sedation provided using different drugs. We conducted this comparative study to see the safety and efficacy of D...

Download PDF file
  • EP ID EP616680
  • DOI 10.26611/101510218
  • Views 176
  • Downloads 0

How To Cite

Manohar Mane, Prashant Lomate, J Paranjape (2019). Evaluation of the accuracy of finger-tip palpation of pilot balloon as amethod to judge endo tracheal tube cuff pressure. Medpulse International Journal of Anesthesiology, 10(2), 157-159. https://europub.co.uk./articles/-A-616680