Evaluation of the Efficacy of Clinical Breast Examination Gloves in the Diagnosis of Breast Lumps

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 6

Abstract

Introduction: Recent studies have questioned the efficacy of mammography in reducing breast cancer-related mortality. Additionally, the efficacies of commercially available gloves marketed as aiding the detection of breast lumps have not been independently verified. Aim: To evaluate the efficacy of clinical breast examination gloves in the detection of breast lumps. Materials and Methods: During the period from October 2011 to June 2012, patients were submitted to clinical examination with and without gloves. This prospective study involved 202 patients who underwent conventional clinical breast examination (test 1) or clinical breast examination with Sensifemme® gloves (test 2). All patients underwent subsequent bilateral ultrasonography (test 3) to confirm the findings of the physical examinations. The Chi-square test was used to compare values, while the kappa concordance index was used to determine the concordance between the diagnostic tests. Results: The mean age of the patients was 43 years; 298 breast lumps were detected. In the clinical examination group (test 1), sensitivity was 54%, specificity was 78%, and accuracy was 57%. These rates for clinical breast examinations with gloves (test 2) were 68%, 58%, and 66%, respectively. The glove increased the diagnosis of breast nodules by 14%; the rate of false-positives was also higher (42% for test 2 compared to 22% for test 1). The accuracy of the glove was found to be superior to clinical examination after 100 patients had been examined. The kappa indices for test 1 vs. test 3 and for test 2 vs. test 3 were 0.15 and 0.16, respectively. Conclusion: Clinical examination using the glove was more effective than clinical examination with bare hands for the diagnosis of breast lumps, as it increased the sensitivity and accuracy of lump detection. However, this was at the expense of a higher false-positive rate, which can lead to further tests, unnecessary biopsies, and patient anxiety. The concordance of clinical examination results (whether performed with or without the glove) with those of ultrasonography is weak. Moreover, the glove has a steep learning curve that may discourage its use in certain circumstances.

Authors and Affiliations

Vanessa Monteiro Sanvido, Andrea Yumi Watanabe, Joaquim Teodoro de Araújo Neto, Simone Elias, Gil Facina, Afonso Celso Pinto Nazário

Keywords

Related Articles

A Study of Men’s Sexuality and their Attitude during their Wives’ Pregnancy

ABSTRACT Introduction: Pregnancy is a very sensitive period that is often accompanied by changes in the couple’s sexual relationship due to various physical and psychological changes. Aim: The purpose of this study was t...

Role of Papanicolaou Smear in the Diagnosis of Pathologic Flora in Asymptomatic Patients in Rural Health Care Set-Up

Introduction: The infections of female genital tract, especially the cervix are asymptomatic in presentation and pose a diagnostic challenge. Vaginal infections can lead to cytoplasmic and nuclear abnormalities in the ep...

An Update on Recurrent Early Pregnancy Loss: Causes, Controversies and Cure

ABSTRACT Recurrent Pregnancy Loss (RPL) is an important reproductive issue, affecting 1-5% of couples. It is characterised by repeated miscarriage, impairing the ability to have a live birth. The proven causes are diver...

Determination and Validation of a Lower Cut Off Value of Cerebrospinal Fluid Adenosine Deaminase (CSF-ADA) Activity in Diagnosis of Tuberculous Meningitis

Introduction: Tuberculous meningitis is an infection of the meninges caused by Mycobacterium tuberculosis. It is one of the most common infectious diseases of the Central Nervous System (CNS) and a major health problem i...

A Comparative Study of Serum Uric Acid and Serum Magnesium Level in Diagnosed Cases of Various Renal Disorders

ABSTRACT Introduction: Estimation of serum uric acid and magnesium along with other sensitive markers of renal function (serum creatinine and urea) are very effective to determine extent of renal impairment. Aim: To comp...

Download PDF file
  • EP ID EP350679
  • DOI 10.7860/JCDR/2017/25504.9987
  • Views 73
  • Downloads 0

How To Cite

Vanessa Monteiro Sanvido, Andrea Yumi Watanabe, Joaquim Teodoro de Araújo Neto, Simone Elias, Gil Facina, Afonso Celso Pinto Nazário (2017). Evaluation of the Efficacy of Clinical Breast Examination Gloves in the Diagnosis of Breast Lumps. Journal of Clinical and Diagnostic Research, 11(6), 1-5. https://europub.co.uk./articles/-A-350679