Evaluation of the Outcome of Proximal Humerus Fracture Managed By Internal Locking Plate- A Prospective Study

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2017, Vol 16, Issue 5

Abstract

Background And Objective: Proximal humerus fractures accounts for about 4 to 5% of all fractures. They are the third most common fractures in elderly population after hip and distal radius fractures. Regarding treatment of proximal humerus fractures, controversies still exists whether to do conservative or operative management. Various operative procedures are carried out, recent trend in internal fixation has moved on to locking plates which gives angular stability. The present study is undertaken to evaluate the functional outcome and complications of proximal humerus fractures treated by PHILOS locking plate. Methods: Prospective study involving Adults(18-60years) with proximal humerus fractures admitted to Jubilee Mission Medical College And Research Institute in the period from January 2015 to December 2015. In this study 30 cases of fractures of proximal humerus were treated by open reduction and internal fixation with PHILOS locking plate and followed up for six months. Patients were followed up in outpatient department at first, second, third and sixth months Serial radiographs were taken for assessing complications and the functional outcomes were assessed using Constant and Murley score. Results And Discussion: In our series, male female incidence were equal with majority of patients sustaining fracture following road traffic accident. Average age of patients were 43±11.65 and most common fracture pattern observed in these patients were 3 part fracture (33.3%). 66% of the fractures united within three months and 94% of the fracture united within six months. Average constant score of 65.13 was achieved. Overall complication rates were 20% with one case of osteonecrosis of humeral head. 10% of the patient needed a second unplanned surgery. Fracture pattern and complications had significant impact on the functional outcome of the patient. Conclusion: Internal fixation with PHILOS plate is reliable operative option for displaced proximal humerus fracture which provides angular stable fixation, especially in a osteoporotic bone. High rate of complications depends both on implant design and operative technique. Therefore, attention on technical aspects of applying them would help optimization of the results.

Authors and Affiliations

Dr. T M Jose, Dr. Ajith Vincent, Dr Anil George Paul

Keywords

Related Articles

Mandibular third molar impactions in Puducherry South India – A descriptive cross- sectional study for one year.

Aim and objective: To evaluate the prevalence and patterns of third molar impactions treated in IGMC&RI Materials and methods: Patient treatment records of 150 pts and IOPA were retrieved and analysed for demographic dat...

Evaluation of Breast Architecture and Mass Morphology in Digital Mammography using BIRADS

Breast architectural distortion is an abnormal arrangement of tissue strands and happened linearly as an indicator of breast cancer and conceivably it has a benign cause also. This prospective analytic cross section stud...

A Study of Socio-Demographic and Clinical Profile of Children With Acute Encephalitis Syndrome Presenting To Gauhati Medical College And Hospital, Guwahati

Acute Encephalitis Syndrome (AES) is defined as a person of any age, at any time of the year, with acute onset of fever and a change in mental status (including symptoms such as confusion, disorientation, coma, inability...

Role of elective laparoscopic appendicectomy for chronic right lower quadrant abdominal pain

Backround : Chronic right lower quadrant abdominal pain is still a diagnostic challenge. When other pathologies are ruled out and conservative modalities fail, elective laparoscopic appendicectomy has got a definitive ro...

Effect of Thermocycling and Polyethylene Fibre Addition on Impact and Transversal Strength of Heat Cured Acrylic Resin Denture Base Material

Background: Heat cured acrylic resin is the most widely used material in the manufacture ofdenture base, but has mechanical properties weakness (transversal strength and impact strength). Alternative to increase the mech...

Download PDF file