Evaluation of tibial tray coronal plane alignment in total knee replacement using intramedullary JIG-a prospective study

Abstract

Introduction: Long term survivorship in total knee replacement [TKR] is significantly dependant on prosthesis alignment. In a standard total knee replacement, tibial component alignment is a key factor for the long-term success of the surgery. Materials and Methods: A prospective observational study on 176 subjects who underwent TKR with intramedullary jig for tibial alignment with a minimum follow up period of 6 months was conducted in the Department of orthopaedics, KIMS Al Shifasuper-specialty hospital, Kerala. The Tibial component alignmentwas measured by the Tibial Component Angle [TCA] and Error in Tibial trayalignment. The other outcome variables were knee score, functional score, and Tourniquet time. Results: The mean TCA in the study population was 90.56º±1.194º ranging from 86.45º to 94.05º. The mean error observed in tibial tray alignment was -0.56±1.199 degrees, ranging from -0.45 to + 3.55 degrees. Accuracy of TCA within 90 ± 2 degrees was achieved in 91.48% of subjects. The mean knee score at 6months was 89.45 ± 3.83. The mean functional score at 6months was 87.55 ± 4.93. The mean tourniquet time was 59.08 ± 5.88 minutes. Conclusions: Intramedullary tibial referencing guide can be used in TKR with great accuracy (91.48%) to achieve desired coronal plane tibial component alignment (90o ±2o). When TCA was accurate, knee score and functional score were better than non-accurate TCA cases

Authors and Affiliations

Rahul Sreenivasan Thokaloath, E. G. Mohankumar

Keywords

Related Articles

Incarcerated sigmoid colon with gangrenous appendices epiploicae: A rare case report

Incarcerated inguinal hernia is a common diagnosis in patients presenting with a painful and not reducible groin mass. Sliding hernias are supposed to be more anatomically challenging for a surgeon than an uncomplicated...

Colonoscopic assessment of large bowel diseases and its effectiveness

Introduction: Colonoscopy, for any suspected colonic disease is the first line of investigation. The spectrum of colonic diseases varies from benign to malignant lesions, of which the incidence and mortality differ acros...

Epidemiological profile of Cancer patients in Surgery ward of a tertiary teaching Hospital in the Vindhya region with special reference to high proportion of Carcinoma Gall Bladder

WHO estimates that by 2030, the incidence of Cancer will increase by 68% as compared to 2012. This study evaluates epidemiological profile of Cancer in the Vindhya region. Design: Combination of retrospective and prospec...

A clinical study to predict the outcome of patients with hollow viscus perforation in a tertiary care hospital using manheim peritonitis index

Introduction: Since a longtime multiple effort are been put forwarded to design an effective scoring system as to predict the outcome as to mortality and morbidity of patients admitting to hospitals with hollow viscus pe...

Comparison of outcomes of supracondylar femur fractures treated with locking compression plate vs supracondylar nail

Objective: To compare the outcomes of supracondylar femur (SC) fractures treated with locking compression plate (LCP) with supracondylar nail (SCN). Methods: Analysis of 90 cases was done out of which 45 were treated wit...

Download PDF file
  • EP ID EP498137
  • DOI 10.17511/ ijoso.2018.i4.03
  • Views 286
  • Downloads 0

How To Cite

Rahul Sreenivasan Thokaloath, E. G. Mohankumar (2018). Evaluation of tibial tray coronal plane alignment in total knee replacement using intramedullary JIG-a prospective study. Surgical Update: International Journal of Surgery and Orthopedics, 4(4), 144-150. https://europub.co.uk./articles/-A-498137