Evaluation the FLAIR Sensitivity and DWI Post-inject in Comparison with Delayed Enhancement T1w for Better Detection of Active MS Lesions

Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 4

Abstract

Background: Multiple sclerosis (MS) is a chronic, typically progressive and most common autoimmune disease which damaged the central nervous system. According to the reports in 2008, this disorder has affected 2 and 2.5 million people globally. While the reason is not clear, proposed causes for this include immunologic, environmental, infectious and genetic factors, and sexuality. MS can cause many symptoms, including blurred vision, loss of balance, poor coordination, slurred speech, tremors, numbness, extreme fatigue, problems with memory and concentration, paralysis, blindness, and more. There are four distinguished illness fields in MS: relapsing-remitting MS (RRMS), primary-progressive MS (PPMS), secondaryprogressive MS (SPMS), and progressive-relapsing. MRI is a great tool to identify the asymptomatic distribution of lesions in space and time. Materials and Methods: 32 patients with MS plaques were evaluated by FLAIR and DWI pre- and post-Gadolinium injection compared with 15minutes delay T1w SE. Results: FLAIR post-inject had significantly better detection of the number and signal intensity of active MS lesions. DWI and ADC images detected active plaques different from non-active lesions without contrast. Conclusion: The result of this study showed that FLAIR post-inject had the highest sensitivity in detection of active MS lesions due to the CSF signal suppression in FLAIR, thus offering enough TR time recovery in active enhanced plaques.

Authors and Affiliations

M. Hoseinipourasl, J. Abdolmohammadi, K. Sharifi, S. Miraki

Keywords

Related Articles

A New Conveyable Device for Electrodrainage of Thorax

Chest tube is a flexible plastic tube used to discharge secretion in the cavity between the lungs and chest named pleural cavity. Normally, there is a small amount of fluid in the cavity between the lungs and chest; This...

The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and Objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, patients who were suspicious of having MS wh...

Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology pr...

Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams

Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measur...

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis o...

Download PDF file
  • EP ID EP457318
  • DOI -
  • Views 90
  • Downloads 0

How To Cite

M. Hoseinipourasl, J. Abdolmohammadi, K. Sharifi, S. Miraki (2018). Evaluation the FLAIR Sensitivity and DWI Post-inject in Comparison with Delayed Enhancement T1w for Better Detection of Active MS Lesions. Journal of Biomedical Physics and Engineering, 8(4), 365-374. https://europub.co.uk./articles/-A-457318