EXERGETIC EFFICIENCY SPLIT-CONDITIONERS OF “DAIKIN” FIRM

Abstract

In the modern air-conditioning systems with air split-conditioners, equipments, refrigeration agents and processes are occupied the important place, the objective assessment of the degree of its energy perfection which could be defined only on the basis of their exergy analysis. The purpose of the work is to establish exergetic efficiency and losses of exergy in separate elements of the refrigeration machines of the split-conditioners of “Daikin” firm of different cooling capacity. The author’s innovative mathematical model for the exergetic method for analyzing the work of one-stage refrigeration machines with refrigeration agent R410A, which are used in air split-conditioners of “Daikin” firm model series ATXN-MB, for the purpose of computer evaluation their energy efficiency through exergetic output-input ratio (OIR) depending on the various factors influencing their work, was used in this article. The exergetic OIR of air split-conditioners was determined from its exergy balance for 1 kg/s of the cost of the circulating working refrigerant. The exergetic OIR and losses of exergy in separate elements of the air split-conditioners with standard cooling capacity 2050, 2560, 3410, 5480, 6230 W of “Daikin” firm at standard external temperature conditions are determined. It has been established that with increasing of air split-conditioner cooling capacity the exergetic OIR decreases from 23,1 % to 19,4 %, which is by 16,0 %, what is negative. The losses of exergy in all elements of refrigeration machines of the air split-conditioners are installed, which indicates that elements of the air split-conditioner need to be improved to reduce losses of exergy in them, and the overall increasing in the exergetic OIR.

Authors and Affiliations

Volodymyr Labay, Vitaliy Yaroslav, Oleksandr Dovbush

Keywords

Related Articles

Моделювання повітророзподілу в приміщенні у змінному режимі за допомогою моделі турбулентності Спаларта – Алмараса

The article is devoted to the decision of actual task of air distribution efficiency increasing with the help of swirl and spread air jets to provide normative parameters of air in the production apartments. The mathemat...

ДЕФОРМАТИВНІСТЬ ВУЗЛІВ ДЕРЕВ’ЯНИХ КОНСТРУКЦІЙ НА З’ЄДНАННЯХ ТИПУ “СТАЛЬ-ДЕРЕВИНА”

Nowadays design of timber buildings and constructions growth up. It is connected with the dissemination of eco-technologies, efficient energy-saving buildings, rapid constructing, inexpensive solutions and addicting to s...

ВПЛИВ ЗНАЧЕННЯ КУТІВ ПРИЄДНАННЯ ВХІДНИХ СТРУМЕНІВ НА НЕРІВНОМІРНІСТЬШЛЯХОВОГО ПРИТОКУ ВОДИ ДО НАПІРНОГО ТРУБОПРОВОДУ-ЗБИРАЧА

Results of the experimental investigation of water inflow into a pressure pipe-collector (PC) depending on the value of the inflow angle b of the input jets are presented. The inner diameter of the experimental PC was of...

ЕКСПЕРИМЕНТАЛЬНІ ДОСЛІДЖЕННЯ ДЕФОРМАТИВНОСТІ І МІЦНОСТІ ПОПЕРЕДНЬО НАПРУЖЕНОЇ ЗБІРНО-МОНОЛІТНОЇ БАЛКИ ПРОГОНОВОЇ БУДОВИ ПРОЛЬОТОМ 12 М

The paper presents only some problems of design and constraction of the bridge. The active provides the results of the research out composite muilti-span prestressed reinforced concrete beam for time building bridges. Co...

Розрахунок за деформаційною моделлю залізобетонних колон, підсилених вуглецевою стрічкою

In this paper for calculation of reinforced concrete columns strengthened with carbon laminate with suggestions based on the method of calculation according to the recommendations NIISK and Sika on the basis of deformati...

Download PDF file
  • EP ID EP494692
  • DOI -
  • Views 81
  • Downloads 0

How To Cite

Volodymyr Labay, Vitaliy Yaroslav, Oleksandr Dovbush (2018). EXERGETIC EFFICIENCY SPLIT-CONDITIONERS OF “DAIKIN” FIRM. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(888), 87-92. https://europub.co.uk./articles/-A-494692